6. If the image is not parallel to the screen, rotate the integrator rod.
7. If the edges of the image are not in focus, loosen the two set screws on the end of the optical housing and
then move the handle (
A
) attached to the lens backward and forward.
8. Verify there an no shadows on the screen. If shadows appear, see
Align the Fold Mirror on page 2-2
9. Tighten all of the integrator rod set screws.
10. Replace the top lid.
2.2
Align the Fold Mirror
If a corner or edge of an image is missing, the fold mirror might be misaligned with the optical system. To
correct this issue:
1. Remove the top lid and set it aside. See
Remove the Top Lid on page 3-4
.
2. Display a full white test pattern:
a. On the touch panel controller (TPC), tap the
Test Pattern
icon (
)
in the task bar.
b. Tap
All Test Patterns
.
c. Tap
RBG-12bit-Full Screen White
.
3. Insert a hex driver in the first set screw (A) and a hex driver in the first cap screw (B).
4. Equally turn the set screw (A) and cap screw (B) in opposite directions until the black corner is removed.
A
Set Screw (x2)
B
Cap Screw (x2)
A
A
B
A