GS Series 630-635 Service Manual
57
020-001224-02 Rev. 1 (08-2018)
Ventilation and cooling
Vents and louvers provide ventilation, both for intake and exhaust, keeping the projector
components within their operating temperature specifications.
Do not install the projector near a radiator, heat register, or within an enclosure. To ensure
adequate airflow, follow the requirements specified in the line drawing (P/N: 020-001122-XX) and
never block or cover the vents.
When replacing fans, ensure you confirm the fan direction for airflow. The correct orientation of the
fan also ensures that the fan harness reaches the connector.
Replacing fans 1 and 2
The fans 1 and 2 draw the hot air out of the projector and provides exhaust cooling for the light engine
and electronics.
1. Remove the right-side cover.
2. To separate the affected fan from the right-side cover, remove the four M3 screws with a Phillips
#1 screwdriver.
3. Separate the fan holder and fans.
4. Replace the affected fan.
5. To re-install, follow these steps in reverse order.
Replacing fan 3
The fan 3 provides the
intake air cooling for the DMD assemblies in the light engine and the red laser
driver bank.
1. Remove the top, rear, and left-side covers from the projector.