Service setups
GS Series 630-635 Service Manual
15
020-001224-02 Rev. 1 (08-2018)
PC mode
When performing a functional test, to optimize the image before testing, adjust the zoom and
focus.
• 1080P: Analog 1920 x 1080 @60Hz
• WUXGA: Analog 1920 x 1200 @60Hz
Adjusting color performance
Use the HDTV (408p, 720p, 1080p) source to complete the test. The color does not turn purple and
blue.
1. If the image is noisy, press Menu > Screen > Pixel Phase and adjust the phase.
2. If blue color appears abnormal under the 64 Gray RGBW pattern, to complete a Phosphor Index
adjustment, enter Service mode.
See
3. If the color appears abnormal under the 256 Gray pattern, to do a Filter Index adjustment,
enter Service mode.
See
Warning! Failure to comply with the following could result in death or serious injury.
• Do not look into the projector lens when the laser is on. The extremely high brightness can cause
permanent eye damage.
Warning! Failure to comply with the following could result in death or serious injury.
• Do not look into the projector lens when the laser is on. The extremely high brightness can cause
permanent eye damage.
ID
Part name
Description
1
Test equipment
Video generator
2
Test signal
480p, 720p, 1080p
3
Test pattern
Master, 64 Gray RGBW or SMPTE BAR, 256 Gray
4
Inspection items
• Check if the color level is supersaturated.
• If the color level is supersaturated, the 64 Gray RGBW test pattern appears blurred
and fuzzy.
5
Criteria
• Colors in 64 Gray RGBW test pattern appear sharp and clear.
• No noise is visible on the screen.