Caution! If not avoided, the following could result in minor or moderate injury.
•
Do not look directly into the lens when the light source is on. The extremely high brightness can
cause permanent eye damage.
When performing boresight adjustments, the goal is to balance the tilt of the lens mount to
compensate for screen-to-projector tilt but also to precisely maintain the original factory settings of
the lens mount axial position.
1. Remove the lens surround.
2. Display the Boresight test pattern.
3. Loosen the lock screws highlighted in the image below.
4. Turn the right boresight screw 1/16 of a turn clockwise.
Adjusting the image
CP2415-Xe Installation and Setup Guide
38
020-103584-02 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.