6. Once the required adjustment is made, tighten the lock nut against the bottom of the projector
(B in the image in step 5).
Optionally connecting the exhaust duct
Connect the exhaust duct to provide ventilation for the projector.
Install the optional duct (P/N: 119-103105-XX) if an air volume of 9,000 BTU (per hour) cannot be
ventilated from the room in which the projector is installed.
When using an external duct, the duct must include a heat extractor and blower that maintains a
minimum of 450 cubic feet per minute (CFM) at the projector exhaust opening when the projector is
operating at 25°C (77°F) at an elevation of 914 meters (3,000 feet) or less.
If insufficient airflow exists, add an extractor or a booster. Do not mount the extractor on the projector
as this may introduce vibration into the image.
1. Align the duct with mounting holes on the side of the projector.
2. Hold the duct in position and secure it to the projector with four screws.
Installing the lens
The lens seals the projection head, preventing contaminants from entering the main electronics area.
Caution! If not avoided, the following could result in minor or moderate injury.
•
Do not operate the product without a lens installed.
•
Always use a lens plug when installing or moving the product. This prevents contaminants from
entering the product.
1. Turn off and unplug the projector.
2. On the front of the projector, move the lens clamp to the open position.
Installation and setup
CP2415-Xe Installation and Setup Guide
19
020-103584-02 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Содержание CP2415-Xe
Страница 1: ...Installation and Setup Guide 020 103584 02 CP2415 Xe...
Страница 48: ......