12. Connect to power (on page 24).
•
For the UL version, trim the length of the power cable as necessary.
•
For the CE version, no pre-installed power cable is supplied.
13. Install the disinfecting module in the receiver box (on page 17).
14. Install the ceiling tiles removed in step 2.
15. Repeat steps 1 to 14 for each receiver box.
Mounting receiver boxes recessed in the ceiling with a block
and hanger
Recessed mounting in the ceiling works with a mounting block adapter (P/N: 174-107109-XX) and
third-party Erico
™
hanger or an equivalent mounting fixture.
Warning! If not avoided, the following could result in death or serious injury.
•
Ensure load wires and anchoring comply to local building regulations and codes.
•
Ensure load wires are connected between the receiver box, mounting structure, and the load
bearing surface (higher than the tile) according to local building regulations and codes.
The following Erico commercial hangers are compatible with CounterAct and must be provided by the
site owner:
Erico type
Description
51220A
20’ T-grid span vertical adjustable
512A(512ATC)
24’ T-grid span vertical adjustable
1. Ensure the power is turned off at the source.
Installation and setup
CounterAct Installation and Setup Guide
31
020-103456-02 Rev. 1 (12-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.