AC input
G
Ground/Earth
N/-
Neutral
For the UL version, if the pre-installed power cable must be removed, perform the following steps.
For the CE version, no pre-installed power cable is supplied and perform the following steps to connect
the power.
1. Remove the disinfecting module from the receiver box (on page 18) to access the power
coupler on the receiver box.
2. Loosen the screw and move the metal clip toward the outer ring.
3. Open the connector housing to access the power terminal block.
4. For the UL version, remove the pre-installed power cable, if necessary.
For the CE version, no pre-installed power cable is supplied.
5. Install either the cable gland or the metal conduit fitting as per the appropriate country's
regulations.
•
Cable gland—Cable outer diameter must be greater than 6 mm (0.23 inches) and less
than 12 mm (0.47 inches)
•
Metal conduit fitting—12.7 mm (1/2 inch), flexible
6. Put the bare ends of the wires into the terminals of the socket.
7. Tighten the three terminal screws.
Installation and setup
CounterAct Installation and Setup Guide
25
020-103456-02 Rev. 1 (12-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.