6-12-3 FAULT RESET BY PILOT sequence
This sequence shows the operation when the FAULT RESET BY PILOT is set at
ON and the error reset is not made after the fault is detected but the reset start
is made by the pilot input.
Pilot input
OFF
Valve output
OFF
Weld current
OFF
Weld complete
output
OFF
Fault output
OFF
ISQ SQ US WT1 CT WT2 HT
OT
number of
pulsation repeat
In repeat mode
ISQ : Initial Squeeze Time
CT : Cool Time
SQ : Squeeze Time WT2 : #2 Weld Time
US : Up Slope Time HT : Hold Time
WT1 : #1 Weld Time OT : Off Time(in repeat mode only)
Fig.6-8
Note : The above chart shows a case where PULSATION is set for one time.