![CHOWEL PATC--150A-EU Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/chowel/patc-150a-eu/patc-150a-eu_instruction-manual_2603266057.webp)
CHOWEL / PATC-150A-EU
- 48 -
. SEQUENCE WHEN DETECTION IS MADE AFTER THE WELD
Pilot input
OFF
Valve output
OFF
Weld current
OFF
Weld complete output
If Weld Complete is ON
in case of fault
OFF
Fault output
OFF
Fault reset input
OFF
ISQ SQ US WT1 CT WT2
HT
ISQ : Initial Squeeze Time
CT : Cool Time
SQ : Squeeze Time WT2 : #2 Weld Time
US : Up Slope Time HT : Hold Time
WT1 : #1 Weld Time OT : Off Time(in repeat mode only)
Fig.6-7
Note : The above chart shows a case where pulsation is set for one time.
Содержание PATC--150A-EU
Страница 20: ...CHOWEL PATC 150A EU 11 Pulsation 1 9 times...
Страница 65: ...CHOWEL PATC 150A EU 56 1 Weld program sheet...
Страница 67: ...CHOWEL PATC 150A EU 58 3 I O connection diagram...
Страница 68: ...CHOWEL PATC 150A EU 59 4 RC 05 wiring diagram...
Страница 69: ...CHOWEL PATC 150A EU 60 5 Outside view of PATC 150A EU...
Страница 70: ...CHOWEL PATC 150A EU 61 6 Outside view of TB 30...
Страница 71: ...CHOWEL PATC 150A EU 62 7 Outside view of RB 10...
Страница 72: ...CHOWEL PATC 150A EU 63 8 Electrical connection for step down T R and SCR...
Страница 73: ...CHOWEL PATC 150A EU 64 9 Connection diagram for Timer Box connector 10 Connection diagram for SCR Box connector...