![CHOWEL PATC--150A-EU Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/chowel/patc-150a-eu/patc-150a-eu_instruction-manual_2603266021.webp)
CHOWEL / PATC-150A-EU
- 12 -
3-4-9 Input signals
. Pilot : 4 (15 schedule, binary 4 bit)
. Weld/No weld : 1 element
. Count reset : 1 element
. Stepper reset : 1 element
. Fault reset : 1 element
. Input open circuit voltage : 24V DC
. Input short circuit current
: 12mA
3-4-10 Control output signals
. Gun valve output
: 2 elements
Gun valve output capacity : DC 24V, 0.5A
. Weld complete : 1a
. Count up : 1a
. Stepper complete : 1a
. Fault : 1a
. Contact load voltage : AC130Vrms, DC170V(Cont. max. value)
. Contact load current : 0.15A (Cont. max. value)
3-4-11 Stepper function
. Stepper schedule : 2 ( On each valve output)
. Number of step : 5 (0
4 step)
. Weld counter range
: 0
9999 (0 step : 1
9999)
. Current range : based on step #0 × 50%
200%
3-4-12 Counter
. Counter schedule
: 2 (On each valve output)
. Counter range
: 1
99,999,999
3-4-13 Fault detection
. Controller failure
. Low line voltage
. Illegal power frequency
. Low voltage in weld
. Memory data error
. Current program error
. No current fault
. SCR short
. 2nd cable break
Содержание PATC--150A-EU
Страница 20: ...CHOWEL PATC 150A EU 11 Pulsation 1 9 times...
Страница 65: ...CHOWEL PATC 150A EU 56 1 Weld program sheet...
Страница 67: ...CHOWEL PATC 150A EU 58 3 I O connection diagram...
Страница 68: ...CHOWEL PATC 150A EU 59 4 RC 05 wiring diagram...
Страница 69: ...CHOWEL PATC 150A EU 60 5 Outside view of PATC 150A EU...
Страница 70: ...CHOWEL PATC 150A EU 61 6 Outside view of TB 30...
Страница 71: ...CHOWEL PATC 150A EU 62 7 Outside view of RB 10...
Страница 72: ...CHOWEL PATC 150A EU 63 8 Electrical connection for step down T R and SCR...
Страница 73: ...CHOWEL PATC 150A EU 64 9 Connection diagram for Timer Box connector 10 Connection diagram for SCR Box connector...