![CHOWEL PATC--150A-EU Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/chowel/patc-150a-eu/patc-150a-eu_instruction-manual_2603266047.webp)
CHOWEL / PATC-150A-EU
- 38 -
c. If the NUMBER OF STEPS should be less then 4, any number of steps can
be used by setting the STEP WELD COUNTS on the way at 0 to skip it.
d. After completing the stepper operation, the weld control is continued in
accordance with the setting of the 4 step. To use the output while the final
step is in operation, set the STEP CURRENT RATE for the 4th step.
e. The final step is always the 4th step. To use the output while the final step
is in operation, set the STEP WELD COUNTS for the 4th step at any other
value than 0.
f. The reset operation can be reset by setting the STEPPER RESET method,
whether it is used or not.
. STEPPER OPERATION
As shown in the following diagram, set the stepper so that the weld is counted
and the weld current can be gradually increased as the electrode tips wear.
Weld
current
STEP 2 COUNTS
Step 4 (final step)
Step 3
Step 2
FINAL STEP OUTPUT ON
Step 1
STEPPER COMPLETE OUTPUT ON
0
STEPPER SCHEDULE COMPLETE
0
Step 1
current rate
STEPPER RESET
STEPPER RESET
Fig.6-1 Stepper operation
6-9-2 Secondary cable break predict function
In welding in the constant current control mode, if the secondary cable is almost
disconnected, it can not be found. If the disconnection is detected by excessive
drop in the current, replace the secondary immediately.
The secondary cable disconnect predict function is designed to alarm the imminent
disconnection of the secondary cable and have it replaced while the welder is not
in operation and thereby prevent the occurrence of the production line stop.
Содержание PATC--150A-EU
Страница 20: ...CHOWEL PATC 150A EU 11 Pulsation 1 9 times...
Страница 65: ...CHOWEL PATC 150A EU 56 1 Weld program sheet...
Страница 67: ...CHOWEL PATC 150A EU 58 3 I O connection diagram...
Страница 68: ...CHOWEL PATC 150A EU 59 4 RC 05 wiring diagram...
Страница 69: ...CHOWEL PATC 150A EU 60 5 Outside view of PATC 150A EU...
Страница 70: ...CHOWEL PATC 150A EU 61 6 Outside view of TB 30...
Страница 71: ...CHOWEL PATC 150A EU 62 7 Outside view of RB 10...
Страница 72: ...CHOWEL PATC 150A EU 63 8 Electrical connection for step down T R and SCR...
Страница 73: ...CHOWEL PATC 150A EU 64 9 Connection diagram for Timer Box connector 10 Connection diagram for SCR Box connector...