Machine Rating
(KVA)
Conductor size(MM
2
)for cable length(meter)
Isolator fuse
(Amps)
10 meter
25 meter
50 meter
50
25 MM
2
35 MM
2
50 MM
2
100
75
50 MM
2
70 MM
2
150/200
100
70 MM
2
95 MM
2
200
150
120 MM
2
250
REMARK : The cable size is the size when the rate of welding machine's margin
is 100%.
5-4 Control signals
Refer to your system configuration table for the control signal and solenoid
connection that you will need to make. Fig.5-6 shows how can you make
connection.
PATC-150A-EU can connection by terminal block which placed inside of Timer box.
Note that signal inputs are made by switching to a +24 Volts supply which is
provided by the Timer unit. Each input draws a current of 12mA (Max.) when a
signal is applied.
Содержание PATC--150A-EU
Страница 20: ...CHOWEL PATC 150A EU 11 Pulsation 1 9 times...
Страница 65: ...CHOWEL PATC 150A EU 56 1 Weld program sheet...
Страница 67: ...CHOWEL PATC 150A EU 58 3 I O connection diagram...
Страница 68: ...CHOWEL PATC 150A EU 59 4 RC 05 wiring diagram...
Страница 69: ...CHOWEL PATC 150A EU 60 5 Outside view of PATC 150A EU...
Страница 70: ...CHOWEL PATC 150A EU 61 6 Outside view of TB 30...
Страница 71: ...CHOWEL PATC 150A EU 62 7 Outside view of RB 10...
Страница 72: ...CHOWEL PATC 150A EU 63 8 Electrical connection for step down T R and SCR...
Страница 73: ...CHOWEL PATC 150A EU 64 9 Connection diagram for Timer Box connector 10 Connection diagram for SCR Box connector...