3.4 Installing this detector unit
Four pieces of the mounting screw holes (M8, 11mm in depth) are provided on the top surface of
this detector unit. Fix this detector unit to a mounting plate or alternatives with four M8 bolts. The
external views and mounting dimensions are shown in the following figure.
(1) For the IRMA51
and IRMA52
, place this detector unit with the distance of 300mm
from the measuring surface. (This detector unit can be placed from 200 to 400mm.)
(2) The target spot can be confirmed by the visible light irradiated from this detector unit to the
measuring surface.
(3) Prepare a mounting plate in accordance with the conditions at an installation place. Decide the
dimensions of the mounting plate in consideration of the space for wiring, etc.
Relation of distance and target area
3. Installation (Refer to [5. Names and functions].)
Cable gland
(25)
133
52
260
130
120
10
120
65
Inlet/outlet for cooling
2-R1/8
Mounting screw hole
4-M8, depth 11
8
70
120
17
Distance
L (mm)
Target
area (mm)
Distance
L (mm)
Target
area (mm)
200
□
30
200
□
30
300
□
50
300
□
30
400
□
70
400
□
40
Distanc
e
(L
)
Unit: mm