60
Removing the Panels
IMPORTANT NOTE
– The burner assembly can only be removed by a qualified engineer.
Ensure the appliance is cold before commencing work.
Remove the glass (For glass removal see pages 15 & 16).
Remove the urn, burner and burner base assembly.
Remove the panel bracket and screw (see fig. 157) to release the side panel (see fig. 158)
Fig. 157
Fig. 158
Remove the back panel (see fig. 159).
Fig. 159
Remove the panel bracket and screw on the other side then lift the side panel out (see fig.160,
161).
Fig. 160
Fig. 161
Only replace with genuine parts refitting in the reverse order.
Test soundness of all gas connection joints.
Check Spillage.
Commission the appliance.
Содержание Alchemy GFL850URN
Страница 1: ...0...
Страница 5: ...4 Fig 7 Smoke Match Holder Fig 8 Remote Control Handset Fig 9 Pressure Test and Isolation Valve...
Страница 15: ...14 Fig 23...