Install the interrupter block ¼ turn more than hand tight into the valve. Insert the spade connectors in the slots
(possible from both sides). Screw thermocouple hand tight into the interrupter block and tighten ¼ turn to
ensure a good electrical connection. Tighten only the thermocouple not the interrupter block.
Ignition Cable
NOTE:
Do not damage the ignition cable while attaching it to the ignition electrode. When the cable is in place,
avoid contact with sharp objects or edges.
Cables longer than 900mm, avoid contact with metal parts, as this could decrease spark.
Attach ignition cable to receiver tab 2.8 x 0.8mm (SPARK), and connect other side to ignition electrode.
Receiver
NOTE:
To keep the receiver free from debris and dirt, Do not remove the receiver from the plastic bag until all
construction is complete. During a power outage the AC Mains Adapter must be unplugged from the
receiver to operate in battery mode.
Snap the plug of the 8 wire cable in the receptacle on the valve and receiver.
Insert batteries. Do not use metal tools. Using a metal tool could cause a short that may damage the receiver.
Place ON/OFF switch (if equipped) to ON position.
Check the reception. If necessary, correct position of antenna by moving the antenna cable to a position that
allows for good reception.
When the RF-receiver is placed in the appliance, the surrounding metal can reduce reception considerably. The
position of the antenna on the receiver also influences reception.
The antenna must not come in contact or cross the ignition wire, this may render the receiver
inoperable.
GAS CONTROL KNOB SETTINGS
Gas control knobs function as follows (see fig.M4):
KNOB
POSITION FUNCTION
Main Valve
OFF
Prevents main gas flow through valve.
Main Valve
ON
Permits main gas flow through valve if the pilot is lit and thermocouple is
generating sufficient power.
MANUAL knob
MAN
Allows the pilot to be manually ignited and prevents main gas flow.
MANUAL knob
ON
Allows for automatic ignition.
Fig.M4: Combination Control GV60, Connections and Adjustment Options