4” (102mm) Flue Liner
If the appliance is fitted with a flue liner the debris shield will not be required (see fig.14).
NOTE
– Leave enough flue length to allow connection. The minimum flue liner is 2 meters from
the spigot.
The Builders Opening
Use non combustible heat resistant materials for the chimney breast, including the top of the
chimney breast, the material in the chimney breast and the back wall of the chimney breast.
The construction must comply with all relevant regulations.
The appliance can be used with a sound Class 1 unl
ined flue with a minimum diameter of 7”
(178mm). If the appliance is
used with a lined chimney the minimum flue diameter must be 6”
(152.4mm) or above
to accommodate the 4” liner. (see fig. 15)
Fig. 15
Min 7” unlined / Min 6” lined
Min 7” unlined / Min 6” lined