11
Gas Route
For your safety it is law that all gas appliances must be installed by a competent person, in
accordance with the current Gas Safety regulations applicable in the country of use.
Ensure that the gas supply is capable of delivering the required amount of gas, and is in
accordance with the rules in force.
When laying the gas pipe work check the fire unit’s gas inlet location to ensure a smooth run.
Lay the appliance in the desired area
to note where the appliance’s gas inlet location to ensure
a smooth run.
For ease the gas is best run to the left side of the appliance.
An isolation valve or valves must be fitted near to the appliance in an accessible area, meeting
all local and national regulations this is to allow the complete removal of the burner control
assembly, for maintenance or repair.
The best route for the gas is through the base of the appliance to the position shown in fig.19.
(For measurement ‘E’ See table on page 10)
Fig. 19
Top Elevation
If routed through the back of the appliance the position of the knock out plate is shown in fig.
20.
(For measurement ‘E’ See table on page 10)
Fig. 20
Front Elevation
Содержание Alchemy GFL850URN
Страница 1: ...0...
Страница 5: ...4 Fig 7 Smoke Match Holder Fig 8 Remote Control Handset Fig 9 Pressure Test and Isolation Valve...
Страница 15: ...14 Fig 23...
Страница 49: ...48 Fig M10...