29
Fitting the Burner Assembly
NOTE
– All gas work must be carried out by a qualified gas installer to all relevant regulations.
Ensure that the gas supply is capable of delivering the required amount of gas, and is in
accordance with the rules in force.
An isolation valve or valves must be fitted near to the appliance in accordance with national
regulations to allow the complete removal for maintenance or repair.
Before connecting the fire unit purge the pipes from air and debris.
The burner assembly can now be connected to the gas supply.
The gas control is located on the underside of the burner assembly base; the gas inlet is
already fitted with a flexible tube to allow movement (see fig. 88, 89)
Fig. 88
Fig. 89
Supplied with the appliance is an isolation valve / pressure test combined (see fig. 90) fit this to
the gas supply and connect the flexible inlet tube shown below (see fig. 91).
IMPORTANT NOTE
– Avoid kinks in the flexible gas pipe.
Fig. 90
Fig. 91