22
SYSTEM
EN
INTELECT
®
RPW 2 USER MANUAL
OPERATING DATA AND RATINGS
Values displayed on the device are with a tolerance of ±10%
Width.................................................................................................420 mm
Depth .................................................................................................410 mm
Height .............................................................................................. 1140 mm
Standard Weight (with one handset).......................32 Kg (72 lbs)
Ambient temperature......................................................10 °C - 40 °C
Relative Humidity .................................................................30% to 75%
Air Pressure............................................................700 hPa to 1060 hPa
Power Consumption
350 VA (Model 2173DEV)
350 VA (Model 2174DEV)
450 VA (Model 2175DEV)
Input
120V AC~ 50 - 60 Hz 350VA (Model 2173DEV)
220-240V AC~ 50 Hz 350VA (Model 2174DEV)
230V AC~ 60 Hz 350VA
100V AC~ 50 - 60Hz 450VA (Model 2175DEV)
Output
0.3 - 5 bar 1 - 21 Hz (RPW) 1 - 50 Hz (V-Actor) (Model 2173DEV)
0.3 - 5 bar 1 - 21 Hz (RPW) 1 - 50 Hz (V-Actor) (Model 2174DEV)
0.3 - 5 bar 1 - 21 Hz (RPW) 1 - 50 Hz (V-Actor) (Model 2175DEV)
Mode ......................................................................Single or Continuous
Compressed Air Output ....................................................0.3 - 5.0 bar
Power Increment Settings ...........................................................0.1 bar
Pulse Amplitude.................................approx. 2 mm at 3 bar, idling
(without coupling)
Pulse Width ..................................................................approx. 6 - 12 ms
Pulse Frequency.........1 - 21 Hz for RPW, 1 - 50 Hz for Vibration
Fuses......................................................... 2 x T6.3A H 250 V 5x20 mm
Electrical Class ................................................................................CLASS I
Electrical Type (Degree of Protection)..................................TYPE B
Regulatory Risk Class..............IIa according to MDD 93/42/EEC
Mass........................................................................................29 Kg (64 lbs)
Safe Working Load.................................................................5 Kg (11 lbs)
FALCON HANDPIECE TECHNICAL
SPECIFICATIONS
Compressed air input..........................................................1.0 - 5.0 bar
Ambient temperature during operation........................10 - 40 °C
Ambient temperature during storage..............................0 - 60 °C
and transport
Ambient air pressure during operation..............800 - 1,060 hPa
Ambient air pressure during storage...................500 - 1,060 hPa
and transport
Air humidity Storage...............................5 - 95%, non-condensing
and transport
Air operation...............................................5 - 95%, non-condensing
Weight....................................................................................................480 g
SOFTWARE
The software is developed and provided by DJO.
To view the version of the software, press the Settings
button. The version number of the Software can be found
by pushing the display unit version information.
TRANSPORT AND STORAGE CONDITIONS
Ambient temperature..................................................-20 °C - 60 °C
Relative Humidity..............................10% - 90 % no condensation
Air Pressure ...........................................................500 hPa to 1060 hPa
Содержание Intelect RPW 2
Страница 32: ...32 USER INTERFACE EN INTELECT RPW 2 USER MANUAL Select transmitter ...
Страница 43: ...43 USER INTERFACE EN INTELECT RPW 2 USER MANUAL 7 START TREATMENT Press the START button Treatment Running ...
Страница 48: ...48 USER INTERFACE EN INTELECT RPW 2 USER MANUAL 2 DELETE Treatment Data Delete all IDs Delete one ID ...
Страница 49: ...49 USER INTERFACE EN INTELECT RPW 2 USER MANUAL Confirm or cancel Delete all treatment sessions ...
Страница 50: ...50 USER INTERFACE EN INTELECT RPW 2 USER MANUAL Delete one session ...
Страница 55: ...55 USER INTERFACE EN INTELECT RPW 2 USER MANUAL Delete one protocol ...
Страница 61: ...61 USER INTERFACE EN INTELECT RPW 2 USER MANUAL 4 Full screen image Close full screen mode ...