100416 - 8000W TRI-FUEL PORTABLE GENERATOR
OPERATION
21
18
5
9
-L
-SF
Move generator to an open, outdoor area. Point exhaust away. Don’t run
generators in enclosed areas (e.g. not in house or garage).
Mover el generador a un área abierta a la intemperie. Apunte el escape alejado.
No corra los generadores en áreas cerradas (ej. no en una casa o garaje).
Déplacer le générateur vers un espace extérieur en plein air. Garder l’échappement
loin. Ne pas faire fonctionner les
générateurs dans un espace clos (ex.,
pas dans une maison ou un garage).
E
X
H
A
UST
EL
E
S
C
A
PE
L’
EC
H
A
P
P
EMEN
T
POINT AWAY
DIRIJA ALEJADO
DIRIGER LOIN
AUTOMATIC SHUTOFF – YOU MUST:
APAGADO AUTOMÁTICO – USTED DEBE:
ARRÊT AUTOMATIQUE – VOUS DEVEZ :
Move to fresh air and
get medical help if
sick, dizzy or weak.
Mueva al aire fresco y obtenga asistencia medica
si está enfermo, mareado, o débil.
Aller à l'air frais et obtenir de l'aide médicale si
malade, étourdi ou faible.
ACTION LABEL
ETIQUETA DE ACCIÓN
ÉTIQUETTE D'ACTION
When you approach the generator to investigate a shut off, a
blinking
red
LED light in the CO Shield area provides notification
that the generator shut off due to an accumulating CO hazard. The
red LED light will blink for at least five (5) minutes after a shutoff
event.
Move the generator to an open, outdoor area and point the
exhaust away from people and buildings. Once relocated to a safe
area, the generator can be restarted, and the proper electrical
connections made. Introduce fresh air and ventilate the location
where the generator shut off.
When starting, the red and yellow LED will blink ten (10) times
simultaneously to indicate the LED is working.
NOTICE
This blinking does not indicate CO Shield is working, as CO
Shield is working at all times the generator is running. Also,
the LED will not blink (10) times if the generator was restarted
within 1 minute after it was manually shut off. This does not
occur if generator shut off from a high CO event.
If CO Shield system experiences a fault and no longer provides
protection, the generator is shutoff automatically and the
yellow
LED light will blink for at least five (5) minutes to notify you of the
fault.
Call our Technical Support Team at 1-877-338-0999 for repair.
The generator can be restarted, but will continue to shutoff.
CO Shield will detect the accumulation of carbon monoxide from
other fuel burning sources such as engine powered tools, or
propane heaters used in the area of operation. If another generator
is used and the exhaust is pointed at a CO Shield equipped
generator, the CO Shield may initiate a shutoff due to rising carbon
monoxide levels. This is not a fault. Hazardous carbon monoxide
has been detected. You must take action to move and direct the
equipment to better dissipate carbon monoxide far away from
people or buildings.
WARNING
Tampering with the CO Shield
®
system could result in a
hazardous condition and will void your warranty.
Removing the CO Shield module will not allow the generator to
start.