100416 - 8000W TRI-FUEL PORTABLE GENERATOR
OPERATION
24
6. Turn the EZ Start dial to the “LPG/NG CHOKE” position.
Electric Start
7. Press and hold the ignition switch in the “START” position for
2 to 3 seconds.
8. Turn the EZ Start dial to the “LPG/NG RUN” position.
9. Press and hold the ignition switch in the “START” position for
up to 5 seconds or until started.
NOTICE
If the engine is cranked longer than 5 seconds, the engine can
flood and will not start.
10. If engine does not start, wait 10 seconds and repeat step 9.
11. When the engine starts, turn the EZ Start dial to the “LPG/NG
RUN” position if in the “LPG/NG CHOKE” position.
12. Plug in devices.
Manual Start
7. Pull the recoil cord 2 to 3 times.
8. Turn the EZ Start dial to the “LPG/NG RUN” position.
9. Pull the recoil cord until started.
10. When the engine starts, turn the EZ Start dial to the “LPG/NG
RUN” position if in the “LPG/NG CHOKE” position.
11. Plug in devices.