![Champion Global Power Equipment 100416 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/champion-global-power-equipment/100416/100416_operators-manual_2589042033.webp)
100416 - 8000W TRI-FUEL PORTABLE GENERATOR
STORAGE
33
4. When gasoline stops flowing from the carburetor, replace
and tighten the carburetor drain bolt and be sure to properly
dispose of the drained gasoline according to local regulations
or guidelines.
5. Turn the EZ Start dial to the “ENGINE STOP” position.
6. Follow steps 8-12 according to Short Term Storage.
Removing from Storage
NOTICE
If the generator has been improperly stored for a period
longer than 30 days with ethanol blended gasoline in the
gasoline tank and/or carburetor, all fuel must be drained
and the carburetor must be thoroughly cleaned of ethanol
build up. This process involves technically advanced tasks.
For assistance please call our Technical Support Team at
1-877-338-0999.
If the gasoline tank and carburetor were properly emptied of all
ethanol blended gasoline prior to the generator being stored,
follow the below steps when removing from storage.
1. Be sure the EZ Start dial is in the “ENGINE STOP” position.
2. Add gasoline to the generator according to
Add Fuel:
Gasoline.
3. Turn the EZ Start dial to the “GASOLINE RUN” position.
4. After 5 minutes check the carburetor and air filter areas for
any leaking gasoline. If any leaks are found, the carburetor
will need to be disassembled and cleaned or replaced. If
no gasoline leaks are found, turn the EZ Start dial to the
“ENGINE STOP” position.
5. Check engine oil level and add clean, fresh oil if needed. See
Oil Specifications for proper oil type.
6. Check and clear air filter of any obstructions such as bugs or
cobwebs. If necessary, clean air filter according to Cleaning
the Air Filter.
7. Start the generator according to Starting the Engine.