18
Jumper
Black Wire
Red Wire
1. Turn OFF AC power to the operator.
2. Unplug the J15 plug labeled BATT on the control board by squeezing
the plug and pulling it from the control board. This disconnects the
ac/dc power to the control board.
3. Connect a jumper between the positive (+) terminal of one battery to
the negative terminal (-) of the other battery.
4. Connect the red wire from the J15 plug to the positive (+) terminal of
the battery.
5. Connect the black wire from the J15 plug to the negative (-) terminal
of the battery.
6. Plug the J15 plug back into the control board. This will power up the
control board.
NOTE:
You may see a small spark when plugging the
J15 plug into the board.
7. Turn ON AC power to the operator.
8. Turn ON the AC power switch on the operator.
STEP 8 continued...
AC POWER SWITCH
The AC Power switch on the operator will turn the incoming 120/240 Vac power ON or OFF. The operator's AC Power switch ONLY turns off AC power
to the control board and DOES NOT turn off battery power.
AC Power Switch
INSTALLATION
STEP 9
CONNECT BATTERIES
7AH BATTERIES
The batteries are charged in the circuit by the integrated transformer. The batteries are for battery backup.
J15 Plug