11
STEP 2
CONCRETE PAD AND OPERATOR
ATTACHMENT
CHECK the national and local building codes before installation.
NOTE:
When lifting the operator use the handle to avoid damaging
the operator.
1. Install the electrical conduit.
2. Pour a concrete pad (reinforced concrete is recommended). The
concrete pad should be 6 inches above the ground and deeper than
the frost line. Ensure the pad is tall enough to avoid possible flooding.
3. Secure the operator to the concrete pad with appropriate fasteners.
NOTE:
An alternative to a concrete pad is to post mount the operator
(refer to accessories).
4 Concrete
Anchors
1/2" x 3 1/2"
Below the frost line.
Check all national
and local codes.
6" Above Ground
28"
24"
Post Mount
CONDUIT LOCATION
MOUNTING FOOTPRINT
5.5"
4.5"
1"
6.5"
4"
1.5"
10"
3"
28"
20"
15"
24"
13.6"
12.2"
6.1"
2.49"
14"
14.82"
(cover mounting distance)
(Conduit)
(Pad)
INSTALLATION