Emotron VS Series Quick Start Guide
- 134 -
F1.28
Running time of step 10
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.29
Running time of step 11
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.30
Running time of step 12
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.31
Running time of step 13
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.32
Running time of step 14
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.33
Running time of step 15
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.34
Acceleration/deceleration time
of simple PLC reference 0
Range: 0
~
3
Default: 0
F1.35
Acceleration/deceleration time
of simple PLC reference 1
Range: 0
~
3
Default: 0
F1.36
Acceleration/deceleration time
of simple PLC reference 2
Range: 0
~
3
Default: 0
F1.37
Acceleration/deceleration time
of simple PLC reference 3
Range: 0
~
3
Default: 0
F1.38
Acceleration/deceleration time
of simple PLC reference 4
Range: 0
~
3
Default: 0
F1.39
Acceleration/deceleration time
of simple PLC reference 5
Range: 0
~
3
Default: 0
F1.40
Acceleration/deceleration time
of simple PLC reference 6
Range: 0
~
3
Default: 0
F1.41
Acceleration/deceleration time
of simple PLC reference 7
Range: 0
~
3
Default: 0
F1.42
Acceleration/deceleration time
of simple PLC reference 8
Range: 0
~
3
Default: 0
F1.43
Acceleration/deceleration time
of simple PLC reference 9
Range: 0
~
3
Default: 0
F1.44
Acceleration/deceleration time
of simple PLC reference 10
Range: 0
~
3
Default: 0
F1.45
Acceleration/deceleration time
of simple PLC reference 11
Range: 0
~
3
Default: 0
F1.46
Acceleration/deceleration time
of simple PLC reference 12
Range: 0
~
3
Default: 0
F1.47
Acceleration/deceleration time
of simple PLC reference 13
Range: 0
~
3
Default: 0
F1.48
Acceleration/deceleration time
of simple PLC reference 14
Range: 0
~
3
Default: 0
F1.49
Acceleration/deceleration time
of simple PLC reference 15
Range: 0
~
3
Default: 0
Sets the running time for step 0
~
15 of simple PLC. The time unit is set by thousand’s place of F1.17.
0: Means Accel/Decel time 0 that set in (b2.00, b2.01)
1: Means Accel/Decel time 2 that set in (b2.02, b2.03)
2: Means Accel/Decel time 3 that set in (b2.04, b2.05)
3: Means Accel/Decel time 4 that set in (b2.06, b2.07)
F1.50
UP/DOWN function selection of
multi-reference
Range: 00
~
11
Default: 00
F1.51
UP/DOWN speed of
multi-reference
Range: 0.0
~
100%
Default: 0.0%
Frequency of multi-reference can be adjusted by UP/DOWN function, adjustment speed is set by
function code F1.51
Unit’s place:
Action selection when power off
0:Zero clearing when power off
1:keep the value when power off
Ten’s place:
select if it can be reduced to negative
0:Disable
1:Enable