![CG Emotron VS Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/cg/emotron-vs-series/emotron-vs-series_quick-start-manual_2585392013.webp)
Emotron VS Series Quick Start Guide
- 12 -
Ambient
temperature
-10
℃~
40
℃
(VSS/VSR)
-10
℃~
50
℃
(VSM/VSX)
Relative
humidity
5
~
95%, no condensation
Vibration
Less than 5.9m/s2 (0.6g)
Storage
temperature
-20
℃~
+70
℃
Others
Efficiency
Rated power≥93%
Installation
Wall-mounted or Flange mounting
IP grade
IP20
Cooling
method
Fan cooled
2.3.2 Features of Solar Drive
Table 2-4 VSR11 Series Technical features
Input specification
PV Input
Maximum Input DC Voltage
400VDC
Recommended Voc Range
170
~
400VDC
Recommended MPPT
Voltage Range
140
~
240VDC
Starting Voltage Range
80
~
400VDC
Grid or backup generator input
Input voltage
Single phase110V (-15%
~
30%)
Output specification
Rated output voltage
3PH 110V
Output frequency
0
~
600.00Hz
(
default: 0
~
50.00Hz
)
Protection
Built-in Protection
Lightening protection, over-current, overvoltage, output phase-lose,
under-load, under-voltage, short circuit, overheating, water pump dry
run etc.
Table 2-5 VSR23 Series Technical features
Input specification
PV Input
Maximum Input DC Voltage
450VDC
Recommended Voc Range
320
~
370VDC
Recommended MPPT
Voltage Range
250
~
350VDC
Starting Voltage Range
80
~
450VDC
Grid or backup generator input
Input voltage
Single phase 220V (-20%
~
20%)
Output specification
Rated output voltage
3PH 220V
Output frequency
0
~
600.00Hz
(
default: 0
~
50.00Hz
)
Protection
Built-in Protection
Lightening protection, over-current, overvoltage, output phase-lose,
under-load, under-voltage, short circuit, overheating, water pump dry
run etc.
Table 2-6 VSR48 Series Technical features
Input specification
PV Input
Maximum Input DC Voltage
800VDC