2: Repeat cycles
PLC automatically starts another cycle after finishing one until there is a stop command, shown
as Fig. 6-33.
0
f0
a0
T0
a1
f1
f2
f3
f4
f5
f6
f7
f8
f9
f10
f11
f12
f13
f14
f15
a2
a3
a4
a5
d6
a6
a7
a8
a9
a10
a11
d12
a12
a13
a14
a15
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13T14 T15
d0
Run command
PLC cycle completed
Pulse length:250ms
Output frequency(Hz)
f0
Fig 6-33
Ten
’
s place: started mode
0: Continue to run from the step of stop (or fault)
At the moment drive stop, the drive automatically records the running time of current step. When
restarted, the drive will gets into this step, continue to run the Remaining time with the frequency of this
step.
1: Run from the first step “multi-step reference 0”
When restarted after stop, the drive will start to run from “step 0”.
2: Run from the Eighth step “multi-step reference 8”
When restarted after stop, the drive will start to run from “step 8”.
3: Run from the Fifteenth step “multi-step reference 15”
When restarted after stop, the drive will start to run from “step15”.
Hundreds place: power loss memory
0: Memory disabled on power loss
The drive does not memorize PLC running status on power loss and starts the running from step
0 after power up again.
1: Memory enabled on power loss
The drive saves PLC running status on power loss, including the running step, running frequency
and finished running time at the moment of power loss. After the next power up, the running will be
continued in accordance with the memorized status.
Thousands place: unit of simple PLC running time
0: Second (s)
1: Hour (h)
Set the unit of running time and Accel/Decel time of simple PLC.
F1.18
Running time of step 0
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.19
Running time of step 1
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.20
Running time of step 2
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.21
Running time of step 3
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.22
Running time of step 4
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.23
Running time of step 5
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.24
Running time of step 6
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.25
Running time of step 7
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.26
Running time of step 8
Range:0.0
~
6000.0s(h)
Default:0.0s(h)
F1.27
Running time of step 9
Range:0.0
~
6000.0s(h)
Default:0.0s(h)