Emotron VS Series Quick Start Guide
- 143 -
(VSX Only)
U0.22
HO output
(VSX Only)
Range: 0.00
~
100.00kHz
Default: 0.00kHz
U0.23
Temperature of inverter
Range:-40.0
~
120.0
℃
Default: 0.0
℃
U0.24
Accumulative power-on
time
Range:0
~
65535min
Default: 0min
U0.25
Accumulative running time
Range:0
~
65535min
Default: 0min
U0.26
Cumulative power-on time
Range:0
~
65535h
Default: 0h
U0.27
Cumulative running time
Range:0
~
65535h
Default: 0h
U0.28
Count value
Range:0
~
65535
Default: 0
U0.29
Length value
Range:0
~
65535m
Default: 0m
U0.30
Linear speed
Range:0
~
65535m/min
Default: 0m/Min
U0.31
Output torque
Range:0.0
~
300.0%
Default: 0.0%
U0.32
PTC motor temperature
detection
Range: -40
~
200
℃
Default: 0
℃
U0.35
Power consumption
Range: 0
~
65535kWh
Default: 0 kWh
U0.36
VDI1
~
VDI5 input status
Range: 00000
~
11111
Default: 00000
U0.37
VDO1
~
VDO5 output
status
Range: 00000
~
11111
Default: 00000
U0.38
High speed pulse X7 or
the line number of
expansion card monitoring
Range: 0
~
65535
Default: 0
Group U1 Fault Record
U1.00
Code of the latest fault
Range:0
~
31
Default:0
U1.01
Running frequency when
the latest fault occurred
Range:0.00
~
Fup
Default:0.0Hz
U1.02
Output current when the
latest fault occurred
Range:0.0
~
3000.0A
Default:0.0A
U1.03
Bus voltage when the
latest fault occurred
Range:0
~
1200V
Default:0V
U1.04
Cumulative running time
when the latest fault
occurred
Range:0
~
65535h
Default:0h
Check the information of the latest fault. See Chapter 7 for details of fault codes.
U1.05
Code of previous fault
Range:0
~
31
Default:0
U1.06
Running frequency when
previous fault occurred
Range:0.00
~
Fup
Default:0.0Hz
U1.07
Output current when
previous fault occurred
Range:0.0
~
3000.0A
Default:0.0A
U1.08
Bus voltage when
previous fault occurred
Range:0
~
1200V
Default:0V
U1.09
Cumulative running time
when previous fault
occurred
Range:0
~
65535h
Default:0h
Check the information of previous fault. See Chapter 7 for details of fault codes.
U1.10
Before-previous fault code
Range:0
~
31
Default:0
U1.11
Running frequency when
before-previous fault
occurred
Range:0.00
~
Fup
Default:0.0Hz
U1.12
Output current when
before-previous fault
occurred
Range:0.0
~
3000.0A
Default:0.0A
U1.13
Bus voltage when
Range:0
~
1200V
Default:0V