Installation Guide for FibeAir IP-20C-HP
Page 54 of 204
Ceragon Proprietary and Confidential
4.10
Connecting the Ethernet Cable
If you need to assemble the Ethernet cable, follow the instructions in section
4.10.1,
Preparing the Ethernet Cable and Plug-in Field
, then proceed to section
Connection of Ethernet Cable to IP-20C-HP
If you using a pre-assembled Ethernet cable, follow the instructions in section
4.10.2,
Preparing the Ethernet Cable Already Assembled
, then proceed to section
Connection of Ethernet Cable to IP-20C-HP
Note:
To ensure proper grounding and connectivity, it is recommended to
use pre-assembled Ethernet cables.
4.10.1
Preparing the Ethernet Cable and Plug-in Field
Important Note!
To ensure proper grounding, the RJ-45 plug must be shielded,
with a crimping tail.
Table 22: Materials for Preparing Ethernet Data Cables
Marketing Model
Description
CAT5E_SFUTP_Outdoor_50m
CABLE,RJ45 TO RJ45 STR 50M,CAT-5E,ETHER,UV RES
CAT5E_SFUTP_Outdoor_75m
CABLE,RJ45 TO RJ45 STR 75M,CAT-5E,ETHER,UV RES
CAT5E_SFUTP_Outdoor_100m_drum CABLE,MATERIAL,CAT-5E,SFUTP,4X2X24AWG,UV
RESISTANCE,100M
CAT5E_SFUTP_Outdoor_305m_drum CABLE,MATERIAL,CAT-5E,SFUTP,4X2X24AWG,UV
RESISTANCE,305M
IP-20_Glands_kit
KIT 5pcs of M28 GLAND (AA-0597-0)
CAT6a_gnd_kit
Universal Grounding Kit
GBE_connector_kit
RJ45 CAT5E CONNECTORS AND BOOTS KIT (package of
10 connectors)
To prepare the Ethernet cable and plug-in field:
1 Prepare the gland and insert the cable, as described in
on page 42.
2 Strip off approximately 45 mm of the outer insulation jacket from the CAT5E
cable.
3 Do not strip off the end of the cable shield, but rather, twist the shield to form
a braid.