6
Secure the edges of the Diplexer unit to the Dual Coupler or Splitter using the
four M8 captive screws and washers supplied with the Diplexer kit, using
20Nm torque. These screws are colored blue in the following picture. Be sure
to tighten the screws in the same diagonal manner as in the previous step.
4 M8 Screws
7
Attach the Radio unit to the Diplexer unit using the 8 M5 captive screws
supplied with the Radio kit. Position the Radio unit on the Diplexer unit so that
the two location pins mounted on the TRX ports of the Diplexer unit fit into
the corresponding holes in the Radio unit. Perform the fastening in diagonal
fashion as in the previous steps. The location pins are located on either the
left of the upper TRX port and the right of the lower TRX port or the right of
the upper TRX port and the left of the lower TRX port, depending on the
frequency.
8 M5 Captive
Screws
Location
Pin
Location Pin
(Not Shown)
Location
Pin Hole
Location Pin Hole