Installation Guide for FibeAir IP-20C-HP
Page 197 of 204
Ceragon Proprietary and Confidential
SITE ACCEPTANCE CHECKLIST
(continued)
4. OUTDOOR UNIT
Type of ODU mount:
(Direct or Remote mount)
ODU is securely mounted to the antenna or pole
OK
ODU is grounded as per installation instructions
OK
ODU
’
s polarization is as per link requirements
OK
ODU is installed properly and has no physical damage
OK
For Remote-Mount Only:
Remote mount kit is securely mounted to the pole
OK
Flexible waveguide has no physical damage and connectors are
sealed
OK
All flexible waveguide bolts are secured using washers and lock-
washers, as appropriate
OK
Flexible waveguide is secured to the pole
OK
6. CAT5/Fiber Optic CABLE
Overall cable length:
Cable type:
CAT5 connectors assembled properly on the cable
OK
Cable connected securely to ODU and IDU
OK
Cable connector is covered by gland and secure by cable tie at
the ODU
OK
At the ODU, cable has a service/drip loop to prevent moisture
from entering the connector
OK
Cable is secured using suitable restraints to fixed points at
regular intervals (0.5 m recommended)
OK
Cable has no sharp bends, kinks, or crushed areas. All bends are
per manufacturer specifications
OK
Grounding is as per site specifications
OK
Cable point-of-entry to building/shelter is weather-proof
OK
Cable ends are properly labeled
OK