7.1.4
Assembling a Long U-Bend
Long U-Bends are used to connect the radio ports of adjacent OCUs on the far side
from the pole mount.
List of Items
Item
Description
Quantity
Marketing Model
1
IP-20C-HP Branching Long U-
Bend Kit
Depends on
Configuration
FXDH-RM-LU-Bend-06
FXDH-RM-LU-Bend-7-8
FXDH-RM-LU-Bend-11
2
#8-32 Socket Hex Screws
12 Per U-Bend
Embedded in U-Bend
1
–
Long U-Bend
Required Tools
•
Imperial Allen key set
Required Torque
•
#8-32 socket hex screws (embedded in U-Bend)
–
2.5 Nm