Installation Guide for FibeAir IP-20C-HP
Page 168 of 204
Ceragon Proprietary and Confidential
7.2.4
4+0 Dual Polarization
List of Items
Item Description
Quantity Marketing Model
1
IP-20C-HP Radio Unit
2
See Section 2.4.1,
2
IP-20C-HP Branching Pole
Profile
1
Part of OCU Mounting kit,
FXDH-RM-MOUNT-kit
3
IP-20C-HP Branching Pillar
2
Part of OCU Mounting kit,
FXDH-RM-MOUNT-kit
4
IP-20C-HP OCU Kit
2
See Section 2.4.4,
5
IP-20C-HP Termination Kit
2
FXDH-RM-TERM-06
FXDH-RM-TERM-7-8
FXDH-RM-TERM-11
6
IP-20C-HP Branching Short
U-Bend Kit
2
FXDH-RM-U-Bend-06
FXDH-RM-U-Bend-7-8
FXDH-RM-U-Bend-11
7
IP-20C-HP OMT Kit
1
DXDH-MD-OMT-ff
8
Flexible Waveguides
2
Procedure
1 Assemble the OCU Mounting Kit. See Section 7.1.1,
2 Assemble an OCU using a Left Rail Configuration, attach the an IP-20C-HP
radio to the OCU, and connect the radio-OCU assembly to the Branching Pole
Profile. See Section 7.1.2,
3 Assemble the second OCU using a Right Rail Configuration, attach the second
IP-20C-HP radio to the OCU, and connect the radio-OCU assembly to the
Branching Pole Profile. See Section 7.1.2,
3 On the side of the OCU facing the pole, attach Short U-Bends between the
radio ports of the two OCUs. See Section 7.1.3,
4 Connect the OMT to the antenna. See Steps 1-4 in Section 6.5,