page 125
www.centsys.com
Lift the spikes by hand to get them just under the level of the trench plate,
which pushes the linkage arm back, allowing you to move the unit into its
correct position; 20mm from the front edge of the Linkage Cover Plate.
(Section 14, Figure 52).
14.5.2. Fitting and leveling the SECTOR II boom pole
Refer to Section 3.3 of the SECTOR II Installation manual for instructions on
fi
tting and
leveling to boom pole.
SECTOR II
M12x60
Hex Bolt
Heavy duty
washer
Hold down
bracket
Drive linkage
assembly
SECTOR II
Drive linkage
cover plate
20mm
FIGURE 52
FIGURE 53
STEP 3
STEP 4
14.5. Integrating the SECTOR II with the CLAWS
14.5.1. Placing the SECTOR II into position
Drive linkage
unit
SECTOR II
FIGURE 50
STEP 1
SECTOR II
Ground
level
Drive linkage
end cover
Drive linkage
frame
Drive linkage
cover plate
Y
Y
FIGURE 51
STEP 2
RHS FLUSH MOUNT - OPPOSING DIRECTION OF TRAVEL
SECTION 14