     - ID code not matching between the remote controllers and main unit. 
       Delete the Wireless Remote and register again as explained in this manual. 

Problem: 

The Sensing Distance is too short between the Wireless Sensors and the Main Unit. 

Reasons could be: - Some other transmitting equipment in the area could be effecting the wireless range of the system 
                             - The Mains AC voltage is too low or the battery of the Wireless Sensor is low. 

Problem: 

Siren not working. 

Reasons could be: - The wires to the siren are short or broken. 

     - The Siren Hooting time might be set at 00. 

                             - The +ve / -ve wires of the Siren might be connected in reverse polarity.

 

 

.

                                                           Technical Specifications                                                         

.

 

Input 

AC 100V to  280V 

Frequencies used / Modulation Type 

866 MHz / ASK 

Distance covered by wireless sensors 

Approximate 300 ft in open area.(In case of SW / FSW it is 250 ft) 

Standby current  

26 mA at 12V DC 

Working current  

43 mA at 12V DC without Siren 
506 mA at 12V with Internal Siren 

Ambient Temperature 

10

C to +45

Ambient Humidity   

95% Maximum 

Power Adapter 

12V DC 1A 

Built-in Battery Backup     

Rechargeable 7.4V 500mAh Lithium Battery 

Capacity 

Can  connect  to  75  Wireless  Sensors.  (including  Wireless  Remotes  & 
Signal Repeaters). 
Has  8  Wired  zones  &  each  Zone  can  connect  to  unlimited  Wired 
Sensors as  long as the total resistance of the  Sensors and the  wires is 
less than 200 Ohms.  

GSM Module 

Dual Band - GSM 900 / DCS 1800 MHz 
RF Out Put: 33dBm / 30dBm 
RF Receive Sensitivity: < 1108dBm 
Operating Volatge:4.2V 
Support SIM Card

:

 1.8V/3.0V 

                                  

.

     

                                                            

Terms of Warranty                                                              

.

 

Copper Connections Pvt. Ltd warrants that this product is manufactured under stringent quality standards, making it free from defects in material and 
workmanship, as per the following terms and conditions

:

 

1.

 

The  limited  warranty  for  the  system  is  valid  for  a  period  of  twelve  months  from  the  date  of  purchase  or  fifteen  months  from  the  date  of 
manufacture which ever is earlier. 

2.

 

The limited warranty extends only to the original consumer/ purchaser of the product and is not assignable or transferable to any subsequent 
purchaser/ end user. 

3.

 

During the limited warranty period, Copper Connections Pvt. Ltd or its authorised service network will repair or replace, at Copper Connections 
Pvt. Ltd option, any defective product or parts thereof with a new or factory rebuild replacement items and return the product to the consumer in 
working conditions. No charge will be made to the consumer for either parts or labour in repairing or replacing the product.  All replaced parts 
shall becomes the property of Copper Connections Pvt. Ltd.      

4.

 

Repaired product will be warranted for a balance of original warranty period. 

5.

 

Upon  request  from  Copper  Connections  Pvt.  Ltd  or  its  authorised  service  center,  the  consumer  must  provide  purchase  receipt  or  other 
information to prove the date and place of purchase. 

6.

 

This Burglar Alarm System (like any other commercial or residential alarm system) does not guarantee protection against burglary, fire or other  
emergency because of  variety of reasons. 

        A properly installed and maintained system may reduce the risk of a burglary, robbery, fire or other events, but it is not an insurance or a  
        guarantee that such will not occur or that there will be no personal injury or property loss as a result. 

7.

 

In no case shall seller be liable to anyone for any consequential or incidental damages for breach of this warranty, even if the loss or damage is 
caused by the seller’s own negligence or fault. Consequently, seller shall have no liability for any personal injury, property damage or other loss 
based  on  a claim  “The  product failed  to  give  warning  /  alarm”.  However,  if seller  is  held  liable,  whether  directly  or  indirectly, for  any loss  or 
damage arising under this warranty or otherwise regardless of caus

e, seller’s maximum liability shall not in any case exceed the purchase price 

of the product. 

8.

 

The consumer shall have no benefit or coverage if any of the following conditions are applicable: 

a) 

The  product  has  been  subjected  to  abnormal  use,  abnormal  condition,  improper  storage,  exposure  to  excessive  Temperature,  moisture, 
dampness or fire etc., unauthorised modifications, unauthorised connections, unauthorised repairs.  

b) 

Copper Connections Pvt. Ltd was not notified by consumer of the alleged defect or malfunction of the product during the limited warranty period. 

c) 

The product was used with or connected to equipment not fit for use with Copper Connections Pvt. Ltd system or used in other than its intended 
use. 

d) 

INCASE HIGH VOLTAGES APPEAR ON EARTH. 

e) 

THE DAMAGE IS CAUSED BY LIGHTENING OR DUE TO SPIKES/ SURGES/ HIGH VOLTAGES FROM AC MAIN SUPPLY. 

9.

 

The consumer may contact the authorised dealer to call the service personnel for carrying out repairs or maintenance and the same would be 
attended within a reasonable response time assigned to the dealer. The consumer will be billed for parts or labour charges not covered by this 
limited warranty. 

10.

 

The consumer will be billed for parts or labour charges not covered by this limited warranty.

 

11.

  If  the  product  is  brought  to  Copper  Connections  Pvt.  Ltd  for  repairs,  after  the  warranty  period  ,  Copper  Connections  Pvt.  Ltd  normal  service 

policy shall apply and customer shall be charged accordingly. 

12.

  In  no  event  shall  Copper  Connections  Pvt.  Ltd  or  their  authorised  dealer  be  liable  for  special  or  consequential  damages  or  any  delay  in  the 

performance of this warranty due to causes beyond their control. Copper Connections Pvt. Ltd shall not be liable for incidental or consequential 
damage or a loss of anticipated benefits or profits, loss or impairment of privacy of conversation, work stoppage or loss or  impairment of data 
arising out of the use or inability to use the product. Company’s liability in no event and under no circumstances shall exceed the price paid to 
the company for goods stated in the invoice. 

Содержание BAS-G

Страница 1: ...Sounds control Auto Arm Disarm Time Holidays Battery Mode Power Switch Off in CMS Central Monitoring Station Date Time Setting Disarm Delay to ARM Panic Key Panic Key Silent Passwords Password Operat...

Страница 2: ...s for each day of the week User can also enter up to 10 Holidays in the system On those days the system continues in the previous day s status Example If the user has off days on Saturday and Sunday t...

Страница 3: ...level Passwords can only ARM or DISARM the system The History records would show which Password had ARMED DISARMED the system Remote Monitoring Whenever user wants or during Intrusion User can make a...

Страница 4: ...the systems dials out and plays the Siren sound message recorded by the user Optional the Wireless Sensor Number or the Wired Zone Number Refer Voice Message Recording for playing on Telephone calls...

Страница 5: ...wires are also provided with the system The wires from the female connectors are to be connected as per the tables given below 20 Pin Connector Wire Color To be connected to Red Adapter 12V DC Ve Outp...

Страница 6: ...However different Zones can be used for different type of Sensors Wireless Remote Wireless Sensors should be registered in the Main Unit as described under the heading Wireless Sensors Remotes Panic K...

Страница 7: ...in case of intrusion from wired sensor TYPE PAN PIR MS VBR Gas SMK or Misc in case of intrusion from wired sensor Remote in case Panic key is pressed from the Wireless Remote Keypad in case Panic key...

Страница 8: ...the Bypass zones get Armed To program a Zone as a Bypass Zone refer Wireless Sensor Operating Mode Wired Zones Operating Mode To ARM the system in Bypass mode Press Back Space and 7 together on the Ma...

Страница 9: ...0 1400 Quick Exit To ARM the system for the whole day enter ARM Time 0000 and DISARM time 2359 If all the 3 Time Groups of a day are OFF then the previous day s last status Armed Disarmed shall contin...

Страница 10: ...is connected to it The system has built in rechargeable Li batteries If longer back up is required then additional rechargeable 12V 7AH battery can be connected with an Optional Adapter having charger...

Страница 11: ...e programmed as MODE Always ARMED as explained under the heading Wired Sensor Operating Mode Operation Panic activation from the Remote Press PANIC Key Siren starts hooting and the system dials out on...

Страница 12: ...NG of the system with or without Master Password Press SET Enter Master Password 1234 Keep Pressing 2 to select Password Optn Press Press key UP or DOWN to select OFF or ON for this feature Press Quic...

Страница 13: ...or 4 minutes To extend the time dial 1 Another 4 minutes will be extended from the time of dialing 1 Press 2 to activate the siren Press 3 to de active the siren Press 4 to ARM the system Press 5 to D...

Страница 14: ...SIM installed in the BAS and get reply of the SIM balance SIMBAL CCCCC Where CCCCC The Code to check SIM balance given by the service provider Example In case of AIRTEL SIMBAL 123 Siren Hooting time...

Страница 15: ...orted pads represent 0 Note At least one of the pad should be shorted Default value 10111111 i e pad number 2 is shorted and all others are open So the programming in default case would be Enter Maste...

Страница 16: ...ding the range from one Signal Repeater to another Every Signal Repeater consumes one of the 75 Wireless Sensors capacity of the system SW and FSW do not work through Signal Repeaters Deletion This pr...

Страница 17: ...the balance in SIM of BAS 9 Add telephone number XXXX ATELjk ttttttttt j Tel location from 1 6 k E for SMS commands enable D for SMS commands disable tttttttt telephone number max 11 digits 10 Delete...

Страница 18: ...S G panel For all other programming press Settings choose the desired programming and enter your password to Confirm A confirmation SMS for the same will be received from the panel Wireless Sensor Typ...

Страница 19: ...ature is not available on that Telephone number If no Telephone number is entered the system cannot be ARMED Deleting a Telephone number Press Key 3 Enter Master Password 1234 Press UP or DOWN to sele...

Страница 20: ...se of Magnetic Sensor there will be another option to select MS Widout Swch or MS with Switch Press 1 for Widout Swch and 2 for MS with Switch Magnetic Sensor with switch is designed for applications...

Страница 21: ...ether the system is ARMED or DISARMED Silent Normal These Wireless Sensors will function in case of system being ARMED or BY Pass ARMED But there will be no siren sound Silent Always These Wireless Se...

Страница 22: ...ng false alarms caused due to short spikes in wiring Press SET Enter Master Password 1234 Keep Pressing 2 to select Wired Zn Delay Press Back Space Enter Time delay in milliseconds in 3 digits 010 750...

Страница 23: ...urglar Alarm System like any other commercial or residential alarm system does not guarantee protection against burglary fire or other emergency because of variety of reasons A properly installed and...

Страница 24: ...y dispute arising out of this warranty shall be subjected to jurisdiction of the arbitrator within the city of Delhi 15 The decision of Copper Connections Pvt Ltd on defects damages etc shall be final...

Отзывы: