background image

       Enter Master Password (1234) + # 
       

Keep Pressing 2 to select “Holidays” 

       Press # 
       

Press “Up Arrow” key to select day 1, 2, 3, …… 

       

Press  “#”  

       Enter the date + Month + Year (All in 2 digits format) 
                                   

Here, “Back Space” key can be used to edit the entered digits. 

       P

ress “#” to confirm 

       

Press “Quick Exit” to exit 

Deletion of day

:

 

       

Press  “

SET” 

       Enter Master Password (1234) + # 
       

Keep Pressing 2 to select “Holidays” 

       Press # 
       

Press “Up Arrow” key to select day 1, 2, 3, …… 

       Press  

“Back Space” 

       

Press “#” to confirm deletion 

       

Press “Quick Exit” to exit 

Default

:

 No holidays. 

Note

:

 

If wrong date is entered, system will display “Invalid Date”. 

       

Today’s date or previous date is considered wrong by the system  

 

.

                                                                             

Battery Mode - Power Switch Off                                                       

.

 

When AC mains is not present, the system shifts to the battery mode and keeps the system running. 
If it is required to switch OFF the system when running in Battery mode, do the following programming. 
Procedure:    Press BACK SPACE 
                    Enter Master Password (1234) + # + 2 + #  
                    System will switch OFF. 

Note:

 The system gets ON automatically when the mains AC is restored. 

        

:

 The system cannot be switched OFF if mains AC is connected to it. 

        

:

 The system has built-in rechargeable Li batteries. If longer back up is required then additional rechargeable 12V  

          7AH battery can be connected with an Optional Adapter having charger. 

 

.

                                                         

CMS (Central Monitoring Station)  

                                                   

.

 

        With this feature, all or selected events are logged with a Central Monitoring Station maintained by Copper  
        Connections Pvt Ltd. In the event of any intrusion, the attendant at CMS will take necessary action (as desired by  
        the user). This facility can be availed from Copper Connections Pvt Ltd on annual charges  
        basis. 

Programming for activation of the feature: 

        The system is to be given the CMS telephone number through programming. 

  

To Enable the CMS feature: 

                   

Press  “

SET” 

                   Enter Master Password (1234) + # 
                   

Keep Pressing 2 to select “CMS Settings” 

                   Press # 

       Press 2  
       Press 6 and select CMS = Enable or Disable. Press 6 again to alter Enable / Disable.  
       Press # 
       

Press “Quick Exit” 

  

To Enter Telephone Number of the CMS 

                   

Press  “

SET” 

                   Enter Master Password (1234) + # 
                   

Keep Pressing 2 to select “CMS Settings” 

                   Press # 

       Press 1  
       

Press “Back Space” 

       Enter the Telephone Number 
       Press # 

 

       

Press “Quick Exit” 

 

.

                                                                                 

Date / Time Setting

                                                                                     

.

 

                   

Press  “

SET” 

                   Enter Master Password (1234) + # 
                   

Keep Pressing 2 to select “Set Date” 

                   Press # 
                   Press YY + # + MM + # + DD + # + HH + # + MT + # + d + # + Quick Exit 
                     Where, YY= Year 
                               MM= Month 
                               DD= Date 

Содержание BAS-G

Страница 1: ...Sounds control Auto Arm Disarm Time Holidays Battery Mode Power Switch Off in CMS Central Monitoring Station Date Time Setting Disarm Delay to ARM Panic Key Panic Key Silent Passwords Password Operat...

Страница 2: ...s for each day of the week User can also enter up to 10 Holidays in the system On those days the system continues in the previous day s status Example If the user has off days on Saturday and Sunday t...

Страница 3: ...level Passwords can only ARM or DISARM the system The History records would show which Password had ARMED DISARMED the system Remote Monitoring Whenever user wants or during Intrusion User can make a...

Страница 4: ...the systems dials out and plays the Siren sound message recorded by the user Optional the Wireless Sensor Number or the Wired Zone Number Refer Voice Message Recording for playing on Telephone calls...

Страница 5: ...wires are also provided with the system The wires from the female connectors are to be connected as per the tables given below 20 Pin Connector Wire Color To be connected to Red Adapter 12V DC Ve Outp...

Страница 6: ...However different Zones can be used for different type of Sensors Wireless Remote Wireless Sensors should be registered in the Main Unit as described under the heading Wireless Sensors Remotes Panic K...

Страница 7: ...in case of intrusion from wired sensor TYPE PAN PIR MS VBR Gas SMK or Misc in case of intrusion from wired sensor Remote in case Panic key is pressed from the Wireless Remote Keypad in case Panic key...

Страница 8: ...the Bypass zones get Armed To program a Zone as a Bypass Zone refer Wireless Sensor Operating Mode Wired Zones Operating Mode To ARM the system in Bypass mode Press Back Space and 7 together on the Ma...

Страница 9: ...0 1400 Quick Exit To ARM the system for the whole day enter ARM Time 0000 and DISARM time 2359 If all the 3 Time Groups of a day are OFF then the previous day s last status Armed Disarmed shall contin...

Страница 10: ...is connected to it The system has built in rechargeable Li batteries If longer back up is required then additional rechargeable 12V 7AH battery can be connected with an Optional Adapter having charger...

Страница 11: ...e programmed as MODE Always ARMED as explained under the heading Wired Sensor Operating Mode Operation Panic activation from the Remote Press PANIC Key Siren starts hooting and the system dials out on...

Страница 12: ...NG of the system with or without Master Password Press SET Enter Master Password 1234 Keep Pressing 2 to select Password Optn Press Press key UP or DOWN to select OFF or ON for this feature Press Quic...

Страница 13: ...or 4 minutes To extend the time dial 1 Another 4 minutes will be extended from the time of dialing 1 Press 2 to activate the siren Press 3 to de active the siren Press 4 to ARM the system Press 5 to D...

Страница 14: ...SIM installed in the BAS and get reply of the SIM balance SIMBAL CCCCC Where CCCCC The Code to check SIM balance given by the service provider Example In case of AIRTEL SIMBAL 123 Siren Hooting time...

Страница 15: ...orted pads represent 0 Note At least one of the pad should be shorted Default value 10111111 i e pad number 2 is shorted and all others are open So the programming in default case would be Enter Maste...

Страница 16: ...ding the range from one Signal Repeater to another Every Signal Repeater consumes one of the 75 Wireless Sensors capacity of the system SW and FSW do not work through Signal Repeaters Deletion This pr...

Страница 17: ...the balance in SIM of BAS 9 Add telephone number XXXX ATELjk ttttttttt j Tel location from 1 6 k E for SMS commands enable D for SMS commands disable tttttttt telephone number max 11 digits 10 Delete...

Страница 18: ...S G panel For all other programming press Settings choose the desired programming and enter your password to Confirm A confirmation SMS for the same will be received from the panel Wireless Sensor Typ...

Страница 19: ...ature is not available on that Telephone number If no Telephone number is entered the system cannot be ARMED Deleting a Telephone number Press Key 3 Enter Master Password 1234 Press UP or DOWN to sele...

Страница 20: ...se of Magnetic Sensor there will be another option to select MS Widout Swch or MS with Switch Press 1 for Widout Swch and 2 for MS with Switch Magnetic Sensor with switch is designed for applications...

Страница 21: ...ether the system is ARMED or DISARMED Silent Normal These Wireless Sensors will function in case of system being ARMED or BY Pass ARMED But there will be no siren sound Silent Always These Wireless Se...

Страница 22: ...ng false alarms caused due to short spikes in wiring Press SET Enter Master Password 1234 Keep Pressing 2 to select Wired Zn Delay Press Back Space Enter Time delay in milliseconds in 3 digits 010 750...

Страница 23: ...urglar Alarm System like any other commercial or residential alarm system does not guarantee protection against burglary fire or other emergency because of variety of reasons A properly installed and...

Страница 24: ...y dispute arising out of this warranty shall be subjected to jurisdiction of the arbitrator within the city of Delhi 15 The decision of Copper Connections Pvt Ltd on defects damages etc shall be final...

Отзывы: