HH= Hours in 24 Hours mode.
MT= Minutes
d= Week Day from 0 to 6 (0= Sunday & 6= Saturday)
.
Disarm
.
While entering the premises, DISARM the system with any of the following methods within 10 secs of entering the
premises
:
Press “SET” and 1 together on the Main Unit + Enter Master Password (1234) + #
Note
:
If the Display shows WAIT then wait till that disappears & then Press SET+1.
or
Press the “DISARM” Key on the Wireless Remote.
While Disarming the system, it gives one single loud tone.
.
Delay to ARM
.
This is the time delay after system takes action on getting intrusion from any Sensor. This delay also helps in Arming
the system while leaving the premises. The user can ARM the system while being inside the premises and then leave
within this time
:
Press “
SET”
Enter Master Password (1234) + #
Keep Pressing 2 to select “Arm Delay”
Press #
Back Space
Enter Time delay in seconds in 2 digits (00 - 60 Sec.)
Press # + Quick Exit
Default
:
10 secs.
.
Panic Key
.
The Wireless Remote supplied with the system has a Key marked as “PANIC”.
After 3 secs of pressing this key, the Siren will start hooting and the system will start dialing the Telephone Numbers.
This would happen whether the System is in ARMED mode or DISARMED mode.
If desired, more Panic Switches can be registered in the system. Following are the type of Switches that can be added:
Wireless Remotes (one is supplied with the system and more can be registered)
Wired Panic Switches
Programming
:
:
In case of Wireless Remote, add Wireless Remote as explained under the Heading “Wireless Sensors, Remotes
& Panic Keys Registering/Deletion
”
:
In case of Wired Panic Switches, its Zone is to be programmed as MODE = Always ARMED as explained under
the heading “Wired Sensor – Operating Mode”
Operation
:
Panic activation from the Remote.
Press “PANIC” Key.
Siren starts hooting and the system dials out on the Telephone line.
:
Panic activation from the Main Unit
Press “SENSOR” Key & “4” Key together.
Note
:
In case of PANIC code entry from the main unit, there is no KEY PAD sound.
.
Panic Key
– Silent
.
User has the option to press “Panic” or “Silent Panic” keys from Remote / Main Unit.
In case of “Panic”, the system activates the Siren as well as dial out on Tel Line.
In case of Silent PANIC, the system only dials out on Tel Line.
To activate “Silent Panic” from Main, press Key 5 + 6 together.
To activate “Silent Panic” from Remote, press Panic Key & then press “ARM BY PASS” key within 3 secs. If “ARM
BYPASS” key is not pressed within 3 secs then the system will activate as Normal PANIC.
Note
:
Silent Panic is available from Main Unit & Remote Units but not in Wired / Wireless Panic Switches
:
In case of SILENT PANIC code entry from the main unit, there is no KEY PAD sound.
.
Passwords
.
The system has 7 Passwords.
1 Password is a “Master Password” which can do all the programing & all the operations.
5 Passwords are “User Passwords”. They can only ARM, DISARM or BYPASS ARM the system.
1 Password is an “Emergency Password” which starts dialing to stored telephone numbers without siren sound.
All Passwords except Emergency Password can be changed by their respective Passwords. One User Password
cannot change other’s Password.
But Master Password can change User’s Passwords as well as his own.
The default Master Password = 1234
Emergency Password = 0000
In default there is no User Password. Master Password has to enter the User Passwords.
System doesn’t accept 0000 as User or Master Password.
All programming requires Master password.