Introduction

The following presentation is intended to illustrate the equipment and the appliance in 
order to clarify their working and maintenance. It also informs users and technicians of 
possible dangers and about the precautions to be taken for accident prevention.

Signals and warnings

•  Electrical shock risk : also 230 V 

 can be lethal.   

•  Biological danger, risk of infections from epidemic diseases.  

•  General danger sign.  

• High temperature.  

•  Compulsory direction of fl ow or of rotation.  

Signs cannot fully express danger warnings and compulsory notices, therefore it is nec-
essary that the user reads the warnings and keeps them in due consideration. Failure 
to observe a danger sign or warning may harm operators or damage the machine.
Safety devices must not be removed. The structure of the appliance/equipment or their 
functioning must never be modifi ed.

Field of use 

(for the German market only)

According to the annex no.50 of the General Framework of the Administrative Standard 
regarding the minimum requirements for conveying waste water coming from dental 
surgeries to the drainage system, it is necessary to install amalgam separators to treat 
such water containing amalgam.

Working 

(draw. 1 page 41)

Inside the centrifugal separator air is separated from aspirated liquid, then after pass-
ing through the inlet passage (1) the aspirated liquid reaches the evenly spaced holes 
(2) which spread the fl uid uniformly inside the cone and give it a rotary descending 
motion.
When the fl uid reaches the bottom of the cone (4), inversion of the fl ow rotation and 
direction takes place; at that moment of zero speed amalgam particles fall into the bottom 
of the container (5), whereas the liquid rises out of the middle of the cone.
The re-circulation valves 6 and 7 open and close the passage for the drainage of the 
amalgam depurated liquids.

Содержание IDROCICLONE ISO 18

Страница 1: ...334 DE 0351372 ES 0351372 FR 0351372 GB 0351372 EP 0791751 US 5 779 443 CH 0791751 DE 0791751 ES 0791751 FR 0791751 GB 0791751 PT 0791751 AU 93321 ES 107358 FR 222 394 395 PENDING PATENT CATTANI IT M...

Страница 2: ...SE 15 INSTALLATION 16 MOUNTING 17 NOTICES 17 GENERAL WARNINGS AND BIOLOGICAL RISK 17 ROUTINE MAINTENANCE 18 FAULTS REPORT AND POSSIBILE SOLUTIONS 18 EXTRAORDINARY MAINTENANCE AND ROUTINE ANNUAL FIVE Y...

Страница 3: ...12...

Страница 4: ...or their functioning must never be modified Field of use for the German market only According to the annex no 50 of the General Framework of the Administrative Standard regarding the minimum requireme...

Страница 5: ...will find some details listed below SEPARATORE CENTRIFUGO COMPATTO Name SEPARATORE CENTRIFUGO COMPATTO Electric power supply 230 240 V 1 50 Hz 2 8 A 230 400 V 3 50 Hz 2 2 1 3 A Maximum allowed negativ...

Страница 6: ...won t be possible to start the machine again unless the amalgam collection container 5 is replaced Every time an alarm causes the machine to stop a volt free clean contact closes terminals 25 26 draw...

Страница 7: ...since the contained material is toxic and contaminating for epidemic diseases we recommend to handle it with care To receive a list of authorized companies with licence for transport and disposal of t...

Страница 8: ...e installer should train the surgery staff with practical demonstra tions for amalgam container replacement and filter cleaning on new and therefore not contaminated machines Installation connection m...

Страница 9: ...liquid leaks In case of working anomalies or alarms contact the technician Faults report and possibile solutions The amalgam container filling levels are the only alarms directly linked to the Hydro...

Страница 10: ...15 inserting a metallic piece between the two photodiodes The Hydrocyclone control panel or the display will show a visual alarm to indicate that the amalgam level has reached 95 or 100 3 Remove and...

Страница 11: ...tant Remove the liquids and residual debris which are inside the appliance place it in a poly ethylene bag seal and pack it in packaging constructed of 3 layer corrugated board Important notices The m...

Страница 12: ...l ssigkeit Ricircolo Re circulation Umlauf Tubo in ingresso separatore Separator hose inlet Abscheidervorgang Uscita liquido depurato Processed liquid outlet Ablauf der gereinigten Fl ssigkeit Illustr...

Страница 13: ...Fig 2 Draw 2 Abb 2 SEPARATORE D AMALGAMA IDROCICLONE ISO 18 MONTAGGIO AMALGAM SEPARATOR HYDROCYCLONE ISO 18 MOUNTING AMALGAMABSCHEIDER HYDROZYKLON ISO 18 MONTAGE 42...

Страница 14: ...MOUNTING AMALGAMABSCHEIDER HYDROZYKLON ISO 18 MONTAGE all aspiratore to the aspirator zur Saugmaschine D 50 mm ai riuniti to the dental units zu den Behandlungseinheiten D 50 mm Separatore aria acqua...

Страница 15: ...Fig 4 Draw 4 Abb 4 SEPARATORE D AMALGAMA IDROCICLONE ISO 18 MONTAGGIO AMALGAM SEPARATOR HYDROCYCLONE ISO 18 MOUNTING AMALGAMABSCHEIDER HYDROZYKLON ISO 18 MONTAGE 44...

Страница 16: ...ISO 18 COLLEGAMENTO AMALGAM SEPARATOR HYDROCYCLONE ISO 18 CONNECTION AMALGAMABSCHEIDER HYDROZYKLON ISO 18 ANSCHLUSS all aspiratore to the aspirator zur Saugmaschine all aspiratore to the aspirator zu...

Страница 17: ...ndicazione d allarme come visualizzata sul display del circuito AC80 Alarm indication as shown on the display of the circuit AC80 Alarmanzeige wie auf dem Display der Platine AC80 angezeigt Report Cod...

Страница 18: ...SEPARATORE D AMALGAMA IDROCICLONE ISO 18 ISTRUZIONI PER L USO AMALGAM SEPARATOR HYDROCYCLONE ISO 18 DIRECTIONS FOR USE AMALGAMABSCHEIDER HYDROZYKLON ISO 18 GEBRAUCHSANWEISUNG Fig 7 Draw 7 Abb 7 47...

Страница 19: ...ROCICLONE ISO 18 MANUTENZIONE AMALGAM SEPARATOR HYDROCYCLONE ISO 18 MAINTENANCE AMALGAMABSCHEIDER HYDROZYKLON ISO 18 WARTUNG Fig 8 Draw 8 Abb 8 Corpo metallico per test Metallic piece for checking Met...

Страница 20: ...SEPARATORE D AMALGAMA IDROCICLONE ISO 18 MANUTENZIONE AMALGAM SEPARATOR HYDROCYCLONE ISO 18 MAINTENANCE AMALGAMABSCHEIDER HYDROZYKLON ISO 18 WARTUNG Fig 9 Draw 9 Abb 9 49...

Страница 21: ......

Страница 22: ...334 DE 0351372 ES 0351372 FR 0351372 GB 0351372 EP 0791751 US 5 779 443 CH 0791751 DE 0791751 ES 0791751 FR 0791751 GB 0791751 PT 0791751 AU 93321 ES 107358 FR 222 394 395 PENDING PATENT CATTANI IT M...

Отзывы: