
53
Troubleshooting
Error message
Remedy
No pre-programmed program has been
selected
Select a pre-programmed program
no | Prg
The digital welding machines are equipped with an intelligent safety system. This means that apart from the coolant-pump fuse,
there was no need for any melting-type fuses at all. After a possible malfunction or error has been remedied, the welding machine
can be put back into normal operation again without any fuses having to be changed.
Warning!
Before opening up the welding machine, switch it off, unplug it from the mains and put up a warning sign to stop
anybody inadvertently switching it back on again. If necessary, discharge the electrolytic capacitors.
Error messages on the displays
Over-temperature in secondary circuit of
welding machine
Allow the machine to cool down
tS1 | xxx, tS2 | xxx, tS3 | xxx
(xxx stands for a temp. indication)
tP1 | xxx, tP2 | xxx, tP3 | xxx
tP4 | xxx, tP5 | xxx, tP6 | xxx
(xxx stands for a temp. indication)
Over-temperature in primary circuit of
welding machine
Allow the machine to cool down
N.B.!
If any other error message appears on the displays, which is not described here, then the fault is one that can only be put
right by a service technician. Make a note of the error message shown in the display, and of the serial number and configuration
of the power source, and get in touch with our after-sales service.
Cause
EFd | 8.1
tSt | xxx
(xxx stands for a temp. indication)
Err | 049
Err | 051
Err | 052
EFd | 9.1
EFd | 9.2
Fault in the wirefeed system
Arrange the hosepack in as straight a
line as possible; check that there are no
kinks or dirt in the inner liner; check the
contact pressure in the 2-roller (or 4-
roller) drive
Over-temperature in the control circuit
Allow the machine to cool down
Phase failure
Check mains fuse protection, mains
supply lead and mains plug
Mains undervoltage: Mains voltage has
dropped below the tolerance range (+/-
15%)
Check mains voltage
Mains overvoltage: Mains voltage has
risen above the tolerance range (+/- 15%)
Check mains voltage
External supply voltage: Supply voltage
has dropped below the tolerance range
Check external supply voltage
External supply voltage: Supply voltage
has risen above the tolerance range
Check external supply voltage
Motor of drive unit is stuck or defective
Check / change motor of drive unit
Cooling-unit flow watchdog has been trig-
gered
Check the cooling unit; if nec., top up
the coolant and/or vent the water for-
ward-flow hose as described in “Star-
ting up the cooling unit”
no | H2O
Robot not ready
Initialise “Robot ready” signal
-St | oP-
(when the power source is
being operated with an automatic
interface)
“Ignition time-out” function is active: No
current started flowing before the length
of wire specified in the set-up menu had
been fed. The safety cut-out of the power
source has been triggered.
Shorten the wire stickout; press the
torch trigger repeatedly; clean the sur-
face of the workpiece; if necessary,
increase the setting in “Set-up menu”
for the length of wire that is fed before
the safety cut-out is triggered
Err | Ito
Содержание totalarc2 3000
Страница 28: ......
Страница 29: ...Operating Manual...
Страница 57: ...Mode d emploi...
Страница 85: ...Istruzioni per l uso...
Страница 113: ...Manual de instrucciones...
Страница 142: ...TotalArc 3000...
Страница 143: ...TotalArc 3000 Dual Voltage...
Страница 144: ...TotalArc 4000 5000...
Страница 145: ...TotalArc 4000 5000 Dual Voltage...