51
2nd - Second level of Set-up Menu
The following functions are located in a second menu level:
-
PPU (push-pull unit)
-
C-C (cooling unit cut-out)
-
Ito (ignition time-out)
Changing to the second menu level (2nd)
-
Choose the parameter “2nd”, as described in the sections
headed "Acessing the setup-menu"
-
Press and hold the MEM button
-
Press the Process button
-
Release the MEM button
The power source is now in the second menu level (2nd) of the
set-up menu. The function “PPU” (Push-Pull Unit) is now
displayed.
Select function
-
Select the required function with the Process button
-
Set up the function as described in the following sections
Exit from the second menu level (2nd)
-
Press the MEM button
N.B!
Any changes only become active if you switch to a different
function or exit from the second menu level (2nd).
PPU
... Push-Pull Unit (see the section headed “Push-Pull
Unit”)
C-C
... Cooling unit cut-out ... ON / OFF / Aut
Factory setting: Aut (automatic)
Ito
... Ignition Time-Out ... OFF / 5 ... 100 mm length of wire is
fed until the safety cut-out is triggered, factory setting:
OFF
Special 2-step mode for robot interface
N.B.!
The parameters for the “Special 2-step mode for robot
interface” are available when a robot interface or a field-bus
coupler for robot control is connected up to the LocalNet.
I-S
... Starting ... 0 - 200 % of the welding current
Factory setting: 135 %
SL
... Slope ... 0.1 - 9.9 s, Factory setting: 1.0 s
I-E
... End current ... 0 - 200 % of the welding current
Factory setting: 50 %
t-S
... Duration of starting current ... OFF / 0.1 ... 9.9 s
Factory setting: OFF
t-E
... Duration of end current ... OFF / 0.1 ... 9.9 s
Factory setting: OFF
N.B.!
The above parameters are illustrated by a graph in the
section headed “MIG/MAG welding”.
Parameters for "Aluminium 4-step" mode
I-S
... Starting current ... 0 - 200 % of welding current
Factory setting: 135 %
SL
... Slope ... 0.1 - 9.9 s, Factory setting: 1 s.
I-E
... End current ... 0 - 200 % of welding current
Factory setting: 50 %
Parameters for "Spot welding" mode
SPt
... Spot-welding time ... 0,1 - 5,0s, Factory setting: 1.0s
Содержание totalarc2 3000
Страница 28: ......
Страница 29: ...Operating Manual...
Страница 57: ...Mode d emploi...
Страница 85: ...Istruzioni per l uso...
Страница 113: ...Manual de instrucciones...
Страница 142: ...TotalArc 3000...
Страница 143: ...TotalArc 3000 Dual Voltage...
Страница 144: ...TotalArc 4000 5000...
Страница 145: ...TotalArc 4000 5000 Dual Voltage...