3 - CONTROLS AND INSTRUMENTS
To replace
DEF/AdBlue®
into the tank, refer first to the drain procedure described in Chapter 6, then refer to the
procedure described previously in this Section to refill the tank after
DEF/AdBlue®
has run out.
After
DEF/AdBlue®
has been replaced, let the engine run at low idle for about
20 min
. The warnings, the messages
and the icons remain active until the machine control system recognizes that the quality of
DEF/AdBlue®
in the tank
conforms to the required specification.
NOTICE:
If the warnings, the messages and the icons do not disappear after
25 min
, turn the starter key to OFF
position. Wait
1 min
and then turn the starter key to ON position. If again the warnings, the messages and the icons do
not disappear after
15 s
, consult the CASE CONSTRUCTION dealer to check for malfunctioning of the
DEF/AdBlue®
quality detection system.
If any of the following occurs within
40 h
after
DEF/AdBlue®
replacement, or after completion of SCR system repair:
The quality of
DEF/AdBlue®
is abnormal and the detection lasts for
10 s
.
An SCR system abnormality is detected and the detection lasts for
10 s
.
The machine control system immediately resumes the inducement sequence to the step
(C)
.
Rear camera view operating mode.
(C) DEF/AdBlue®
bad quality, or SCR problem.
SCR detection icon slow flashing.
displayed.
Three short beeps.
(D)
After
30 min
with no action taken.
SCR detection icon fast flashing.
displayed.
Continuous beep.
At the step
(D)
, the operation of the machine shall be
stopped. Reach a safe condition for the machine, and
immediately call the CASE CONSTRUCTION dealer for
inspection and repair of the SCR system, and for replace-
ment of the fluid into the
DEF/AdBlue®
tank with the
proper one.
SMIL17CEX0126AA
22
3-95
Содержание CX490D
Страница 8: ......
Страница 40: ...2 SAFETY INFORMATION SMIL20CEX0681HB 2 2 18 ...
Страница 81: ...3 CONTROLS AND INSTRUMENTS Rear camera view operating mode SMIL19CEX2626HB 5 3 29 ...
Страница 83: ...3 CONTROLS AND INSTRUMENTS Rear and right side camera view operating mode SMIL19CEX0529HA 6 3 31 ...
Страница 154: ...3 CONTROLS AND INSTRUMENTS 3 102 ...
Страница 178: ...4 OPERATING INSTRUCTIONS 4 24 ...
Страница 243: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL15CEXY538AB 7 6 49 ...
Страница 298: ...8 SPECIFICATIONS Working ranges CX490D LC SMIL19CEX2007HB 5 8 10 ...
Страница 300: ...8 SPECIFICATIONS Working ranges CX490D RTC SMIL19CEX2008HB 6 8 12 ...
Страница 302: ...8 SPECIFICATIONS Working ranges CX500D LC SMIL19CEX2009HB 7 8 14 ...
Страница 304: ...8 SPECIFICATIONS Working ranges CX500D RTC SMIL19CEX2010HB 8 8 16 ...
Страница 366: ...9 ACCESSORIES 9 60 ...