8 - SPECIFICATIONS
Engine coolant
CASE AKCELA ACTIFULL™ OT EXTENDED LIFE COOLANT
is the reference genuine product for machine service.
NOTICE:
Never add Supplemental Coolant Additives (SCA) when using
CASE AKCELA ACTIFULL™ OT
EXTENDED LIFE COOLANT
.
CASE AKCELA ACTIFULL™ OT EXTENDED LIFE COOLANT
has to be used if refilling of the cooling system is
needed. Refer to the dedicated procedure and recommendations described in Chapter 6.
CASE AKCELA ACTIFULL™ OT EXTENDED LIFE COOLANT
must be used for the replacement of engine coolant
according to the maintenance program of the machine. The replacement shall also be tackled in case of repair or
replacement of components of the cooling system. Refer to the dedicated procedure described in Chapter 6.
The engine cooling system should always be refilled with coolant solution made by mixture of antifreeze and distilled
(deionized) water.
NOTICE:
Never refill the cooling system with only antifreeze. Never refill the cooling system with only water.
Using
CASE AKCELA ACTIFULL™ OT EXTENDED LIFE COOLANT
, a 50/50 mixture of antifreeze and distilled
(deionized) water grants proper performance of the engine cooling system in the above mentioned operating temper-
ature range of the machine.
CASE AKCELA ACTIFULL™ OT EXTENDED LIFE COOLANT
is available as:
• 50/50 PREMIXED coolant solution ready for usage.
• CONCENTRATE antifreeze to be mixed 50/50 with distilled (deionized) water.
NOTICE:
If operating in extreme winter climate, a coolant solution made by 60/40 antifreeze/distilled (deionized) water
mixture must be used in order to grant proper performance of the engine cooling system.
NOTICE:
Never use coolant solution with more than
60%
of antifreeze. This affects the cooling capacity of the mixture.
When the coolant solution is prepared starting from the CONCENTRATE product, the antifreeze concentration in the
mixture of antifreeze and distilled (deionized) water can be determined with a refractometer designed to measure
ethylene glycol content.
If distilled (deionized) water is not available, use water for dilution with the following properties:
Property
Maximum limit
Total Solids
340 ppm
Total Hardness
170 ppm
Chloride (Cl)
40 ppm
Sulfate (SO4)
100 ppm
Acidity pH
5.5 to 9.0
NOTICE:
Never use hard water, sea water and softened sea water that has been conditioned with salt. The minerals
and salts present in potable water can cause corrosion and deposits resulting in shortened engine life.
8-4
Содержание CX490D
Страница 8: ......
Страница 40: ...2 SAFETY INFORMATION SMIL20CEX0681HB 2 2 18 ...
Страница 81: ...3 CONTROLS AND INSTRUMENTS Rear camera view operating mode SMIL19CEX2626HB 5 3 29 ...
Страница 83: ...3 CONTROLS AND INSTRUMENTS Rear and right side camera view operating mode SMIL19CEX0529HA 6 3 31 ...
Страница 154: ...3 CONTROLS AND INSTRUMENTS 3 102 ...
Страница 178: ...4 OPERATING INSTRUCTIONS 4 24 ...
Страница 243: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL15CEXY538AB 7 6 49 ...
Страница 298: ...8 SPECIFICATIONS Working ranges CX490D LC SMIL19CEX2007HB 5 8 10 ...
Страница 300: ...8 SPECIFICATIONS Working ranges CX490D RTC SMIL19CEX2008HB 6 8 12 ...
Страница 302: ...8 SPECIFICATIONS Working ranges CX500D LC SMIL19CEX2009HB 7 8 14 ...
Страница 304: ...8 SPECIFICATIONS Working ranges CX500D RTC SMIL19CEX2010HB 8 8 16 ...
Страница 366: ...9 ACCESSORIES 9 60 ...