30
F15
FUNCTION : Free Fall Weight
Set free fall weight which will be used in batching operation
F16
FUNCTION : High Limit Weight
Set high limit weight which will be used in batching operation
F17
FUNCTION : Low Limit Weight
Set low limit weight which will be used in batching operation
F18
FUNCTION : Timer – Start Delay Time
DISPLAY
DESCRIPTION
F18 00
No delay
F18 01
0.1 sec
Set value
( 00 ~ 99 )
F18 99
9.9 sec
F19
FUNCTION : Timer – Operating Delay Time of Finish Signal
DISPLAY
DESCRIPTION
F19 00
Do not use
F19 10
1.0 sec
Set value
( 00 ~ 99 )
F19 99
9.9 sec
Note 1. This function is used to decide the time of signal output which batching operation is
completed.
Note 2. You have to set F19 to 00 if you want to use the F22 function.
If F19 & F22 are set any values at the same time, F22 is disregarded.
Because the priority of F19 is high.