Operating instructions

Air gap sensor

SDP110

80300121 / 00   04 / 2021

GB

Содержание SDP110

Страница 1: ...Operating instructions Air gap sensor SDP110 80300121 00 04 2021 GB...

Страница 2: ...8 2 Main menu and submenus 18 9 Set up 22 10 Parameter setting 23 10 1 Parameter setting via IO Link 23 10 1 1 System commands 23 10 1 1 1 Flashing On flashing off 23 10 1 1 2 Distance teach 23 10 1...

Страница 3: ...ero point calibration pressure 28 10 2 5 11 Switch on switch off delay 28 10 2 5 12 Error behaviour of the outputs 28 10 2 5 13 Lock unlock 28 10 2 5 14 Factory reset 29 10 2 6 Diagnostic functions 29...

Страница 4: ...nit packaging or at www ifm com 1 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunc...

Страница 5: ...this document before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrict...

Страница 6: ...013 mbar 101 3 kPa 15 C and 0 relative air humidity The unit can be set to different standard conditions Electromagnetic compatibility EMC This is a class A product This product may cause radio interf...

Страница 7: ...gue signal flow Analogue signal pressure Input for external distance teach OFF output switched to high impedance 4 3 Distance measurement The unit measures the volume flow flow rate time and thus dete...

Страница 8: ...general the following applies Dmax measuring nozzle at the exit measuring nozzle in mm Dmax in m Dmax none 1 0 250 500 1 1 275 550 1 2 300 600 1 3 325 650 1 4 350 700 1 5 375 750 1 6 400 800 1 7 425 8...

Страница 9: ...imum distance Distance measurement 7 and the final value of the measuring range Technical data must be observed when setting SP rP FL and FH The switching signal in case of a fault is adjustable FOU O...

Страница 10: ...e signal goes to 3 5 mA distance measurement and flow measurement 4 6 Measured value damping Use the damping time dAP to set after how many seconds the output signal has reached 63 of the final value...

Страница 11: ...FH MAW MEW Fig 5 Colour change in the window section cFL Lower limit value cFH Upper limit value MAW Initial value of the measuring range MEW Final value of the measuring range The limits can be freel...

Страница 12: ...rameters to identify the units in the plant Additional parameter and diagnostic functions events compared to the SIO mode Data storage Automatic transfer of parameters when a unit is replaced Logging...

Страница 13: ...ntact u Apply the supplied warning label to the sensor cable u Ensure that the system is free of pressure during installation u The rules and regulations for the installation and operation of compress...

Страница 14: ...u Avoid cracks or tapering between the sensor and the push in fitting u Do not use threads with hexagon socket mounting They can have a negative impact on the flow profile of the sensor and lead to an...

Страница 15: ...its diameter at the outlet The access bore hole of the measuring nozzle has 2 5 x the diameter of the measuring nozzle at the outlet Expanding the access bore hole to an angle of 120 The outlet of the...

Страница 16: ...e Pin Connection 1 L 3 L 4 OUT1 Switching signal distance Switching signal flow Switching signal pressure IO Link OFF output switched to high impedance 2 OUT2 Switching signal distance Switching signa...

Страница 17: ...and display elements 1 Switching status LED for OUT1 2 Switching status LED for OUT2 3 TFT display 4 Keys for changing views and parameter setting Display illumination Unit temperature 70 C brightnes...

Страница 18: ...vigate from the process value display to the main menu and from there to the submenus Process value display 1 Main menu 2 Extended functions EF 6 Min max memory MEM 7 Display settings DIS 3 Output 1 O...

Страница 19: ...UT1 OUT2 CFG MEM DIS COLR SIM rP1 SP1 t SP1 FH1 FL1 AEP2 ASP2 rP2 SP2 t SP2 FH2 FL2 Process value display Fig 13 Main menu EF rES Info OUT1 OUT2 CFG MEM DIS COLR SIM OUT1 OUT2 CFG MEM DIS COLR SIM Mai...

Страница 20: ...g 15 Output 1 OUT1 menu SEL2 ou2 FOU2 OUT2 OU On OFF Hno Hnc Fno Fnc tch I OFF FLOW DIST PRES AEP2 ASP2 SP2 rP2 FH2 FL2 dS2 dr2 EF Fig 16 Output 2 OUT2 menu EF CFG rEF T NOZ diA LFC rEF P coF dAP F dA...

Страница 21: ...0 OFF L2 Flow L2 Pres L1 L3 EF Fig 19 Display settings DIS menu COLR cFH F cFH D cFL D cFL F coL D bk wh red green yellow r cF G cF cFH P cFL P coL P bk wh red green yellow r cF G cF bk wh red green y...

Страница 22: ...signals according to the set parameters During the power on delay time the outputs are switched as programmed ON with normally open function Hno Fno OFF with normally closed function Hnc Fnc If outpu...

Страница 23: ...ftware and the IO Device Description IODD for the unit IODD parameter setting software and information on IO Link at io link ifm Notes on parameter setting Manual of the parameter setting software Lis...

Страница 24: ...in general Intention Action Change from the process value display to the main menu Change to the submenu Use to navigate to the sub menu e g EF then Select the requested parameter or Change to the set...

Страница 25: ...10 2 3 1 Limit monitoring OUTx hysteresis function u Select the OUTx menu u Select oux and set the switching signal Hno hysteresis function normally open Hnc hysteresis function normally closed u Sel...

Страница 26: ...t u Select the OUTx menu u Select SELx and set DIST u Select oux and set the switching signal Hno hysteresis function normally open Hnc hysteresis function normally closed u Select the main menu u Sel...

Страница 27: ...d set the brightness of the display 25 50 75 100 OFF The process value display is switched off in the operating mode energy saving mode Error messages are displayed even if the display is deactivated...

Страница 28: ...nu u Select LFC and set the limit below which a flow is evaluated as standstill 10 2 5 9 Standard conditions u Select the CFG menu u Select rEF P and set the standard pressure u Select rEF T and set t...

Страница 29: ...Lo D Minimum value of the distance measured in the process Hi D Maximum value of the distance measured in the process Lo F Minimum value of the flow value measured in the process flow volume or flow...

Страница 30: ...SDP110 Air gap sensor 30 On The simulation starts The values are simulated for the time set under S Tim Abort by pressing any key OFF The simulation is not active...

Страница 31: ...set standard unit of measurement and other views w After 30 s the unit returns to the standard display 2 1 Running 20 m Running 20 m 0 0 m h 0 00 bar 1 Standard display as set under dis L 2 Overview...

Страница 32: ...etting if necessary Title line Running Process value line NoData Process value invalid u Check process conditions Title line Parameter Error Process value line PARA Parameter setting outside the valid...

Страница 33: ...ock via system Setting keys locked via parameter setting software parameter change rejected u Unlock the unit via IO Link interface using the parameter setting software Title line IO Link flash Proces...

Страница 34: ...pair Only the manufacturer is allowed to repair the unit u Flush the unit at regular intervals with higher pressure maximum 16 bar to remove any soiling in the measuring channel 13 3 Disposal u After...

Страница 35: ...r1 0 FOU1 On OUT2 SEL2 DIST ou2 I ASP2 0 m AEP2 250 m FOU2 On CFG uni F m3 h uni D m uni P bar dAP F 0 6 s dAP P 0 06 s P n PnP NOZ 1 diA 1 00 mm LFC 0 05 m h rEF P 1013 mbar rEF T 15 C coF 0 00 bar D...