![CAS CI-6000A Series Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/cas/ci-6000a-series/ci-6000a-series_manual_2565930049.webp)
50
5) How to input the set-point value
There are four ways to input the set-point value
■
First way (F50 = 0 )
To enter set-point, press the * key for 2 seconds in weighing mode
Note 1. Set F50 to 0 in set mode
Note 2. Shift the position of cursor with
, key and enter set value with , key to
go to next step, press the * key
STEP
DISPLAY
DESCRIPTION
Point
ZEro bA
STEP1
1 - 00000
Zero Band
Shift the position of cursor with , key and
Enter Zero band value with , key
To go to next step, press the * key
oP - Pre
STEP2
2 - 00000
Optional Preliminary
Input first weight
PrELiM
STEP3
3 - 00000
Preliminary weight
Input Preliminary weight
FinAL
STEP4
4 - 00000
Final weight
Input final weight
FALL
STEP5
5 - 00000
Free Fall Weight
Input free fall weight
H - LiMit
STEP6
6 - 00000
High Limit Weight
Input high limit weight
L - LiMit
STEP7
7 - 00000
Low Limit Weight
Input low limit weight
■
Second way (F50 = 0 )
Enter set value from F1 to F17 in set mode.
F11 : Zero Band
F12 : Optional Preliminary Weight
F13 : Preliminary Weight
F14 : Final Weight
F15 : Free Fall Weight
F16 : High Limit Weight
F17 : Low Limit Weight
■
Third way
Enter set-point by using RS-232, RS-485 Communication
Set F33 to 4 in set mode. Refer to set mode. (F33)
Содержание CI-6000A Series
Страница 1: ...2 ...
Страница 8: ...9 4 Measure of Appearance ...
Страница 22: ...23 5 Sealing Method Sealing method of cal switch Sealing method of Load Cell Connector ...
Страница 51: ...52 Normal Batching Diagram Loss in Weight Batching Diagram ...
Страница 52: ...53 USER PROGRAM CONTROLMODE Normal Batching ...
Страница 54: ...55 USER PROGRAM CONTROLMODE Loss in Weight ...
Страница 56: ...57 AUTOMATIC PROGRAM CONTROLMODE Normal Batching ...
Страница 58: ...59 AUTOMATIC PROGRAM CONTROLMODE Loss in Weight ...
Страница 71: ...72 MEMO ...
Страница 72: ...73 MEMO ...
Страница 73: ...74 MEMO ...
Страница 74: ...75 ...