43
10. Test Mode
1) How to go to Test Mode
Open the front cover of indicator. set SW1 DIP3 on.
①
: Select test menu that you wish to test.
②
Please select test menu with arrow keys and press ENTER key.
③
: Test menu is selected. Proceed key test.
④
When test is done, Press ENTER key.
To finish test mode, set DIP3 off.
2) Test Menu (TEST 1 – TEST 8)
TEST 1 : Key test
TEST 2 : VFD display test
TEST 3 : A/D conversion test
TEST 4 : Serial interface test (COM1, COM2)
TEST 5 : Printer test (COM2)
TEST 6 : External input/output test
TEST 7 : Analog Out Test(Option)
TEST 8 : BCD Out Test(Option)
TEST 1
FUNCTION : Key test
KEY
DISPLAY
DESCRIPTION
ENTER: Go to menu
Selection mode
tESt 1
TEST 1 condition
Other keys : Perform test
1 1
Press any key to test then the display
shows its number and code.
Note 1. External input key test is TEST 6.
< Key list >
KEY NO. CODE
KEY
NO. CODE
KEY
NO. CODE
ZERO
1 1 TARE
2 2 K.T 3 3
G/N
4 4 * 5 5
ENTER
6 6
Содержание CI-6000A Series
Страница 1: ...2 ...
Страница 8: ...9 4 Measure of Appearance ...
Страница 22: ...23 5 Sealing Method Sealing method of cal switch Sealing method of Load Cell Connector ...
Страница 51: ...52 Normal Batching Diagram Loss in Weight Batching Diagram ...
Страница 52: ...53 USER PROGRAM CONTROLMODE Normal Batching ...
Страница 54: ...55 USER PROGRAM CONTROLMODE Loss in Weight ...
Страница 56: ...57 AUTOMATIC PROGRAM CONTROLMODE Normal Batching ...
Страница 58: ...59 AUTOMATIC PROGRAM CONTROLMODE Loss in Weight ...
Страница 71: ...72 MEMO ...
Страница 72: ...73 MEMO ...
Страница 73: ...74 MEMO ...
Страница 74: ...75 ...