background image

 

L

L

o

o

n

n

W

W

o

o

r

r

k

k

s

s

 

 

I

I

n

n

t

t

e

e

g

g

r

r

a

a

t

t

i

i

o

o

n

n

 

 

G

G

u

u

i

i

d

d

e

e

 

 

i

i

-

-

V

V

u

u

®

®

 

 

L

L

i

i

n

n

k

k

 

 

a

a

n

n

d

d

 

 

O

O

p

p

e

e

n

n

 

 

L

L

i

i

n

n

k

k

 

 

 

 

                         

 

 

 

 

                    CARRIER CORPORATION ©2018 

                    A member of the United Technologies Corporation family · Stock symbol UTX · Catalog No. 11-808-430-01 · 5/24/2018 

 

Содержание LonWorks i-Vu Link

Страница 1: ...te eg gr ra at ti io on n G Gu ui id de e i i V Vu u L Li in nk k a an nd d O Op pe en n L Li in nk k CARRIER CORPORATION 2018 A member of the United Technologies Corporation family Stock symbol UTX C...

Страница 2: ...ur local Carrier office Important changes are listed in Document revision history at the end of this document CARRIER CORPORATION 2018 All rights reserved throughout the world i Vu is a registered tra...

Страница 3: ...Integration Tool 6 To edit an integration point address 8 4 Connect an SLTA 10 to each i Vu Link Open Link on the LonWorks network segment 9 5 Set up the driver properties 10 6 Verify the controller...

Страница 4: ......

Страница 5: ...upported equipment Any device that supports the LonWorks protocol using SNVT s Network media type EIA 232 to SLTA 10 network adapter Quantity of devices you can physically connect to the i Vu Link Ope...

Страница 6: ...50 networks 73354 for RS 485 networks You need 1 adapter for each i Vu Link Open Link that is connected to a LonWorks network segment Make sure you order the model that matches your network topology S...

Страница 7: ...r each type of LonWorks device For example VAV Controller or Fan Coil Controller Get from the third party representative www lonmark com the LonWorks device See Appendix B page 20 Device address infor...

Страница 8: ...Appendix A page 14 may help you determine whether you need an analog or binary microblock To format a LonWorks address All Lonworks addresses should be assigned to lonworks only when setting up addres...

Страница 9: ...at steps 3 12 to add additional control programs and views 12 In the navigation tree select the i Vu Link Open Link in the router list on the right and click Download All Content NOTE This loads the c...

Страница 10: ...Field Assistant application 2 Double click the third party controller in the navigation tree A dialog window appears 3 Click Export under Integration Points 4 Click Save 5 Browse to a location on your...

Страница 11: ...splay a table of NV s On the row for the SNVT element you want to read from or write to click the Microblock Name field to select the microblock that will do the reading or writing For example to read...

Страница 12: ...erl file that you saved from the LonWorks Integration Tool 14 Click Open and then Continue to upload the file 15 Click Close The LonWorks addresses are now set NOTE The LonWorks Integration Tool crea...

Страница 13: ...0 s EIA 232 port using one of the following methods If you have an EIA 232 RS 232 straight through cable with connectors and an S2 DB9 Adapter Connect the adapter to the control module s port Then con...

Страница 14: ...On the first line of the table Index 0 enter appropriate values in each field See table below 9 In Windows Notepad open the log file that NodeUtil created To see this file in the Notepad Open dialog b...

Страница 15: ...pplication uses this authentication code if the third party device requests authentication 10 Click the Apply to refresh the page Verify the following values in the SLTA Node Status section SLTA Comm...

Страница 16: ...that has the error you are troubleshooting In the i Vu or Field Assistant interface view the control program s Properties page Network Points tab to see all the refresh times 1 Connect your computer...

Страница 17: ...appropriate step 13 14 15 or 16 to turn on capture of that item 14 After diagport type go Press Enter 15 Run the capture for one of the following periods of time If all microblock refresh times are o...

Страница 18: ...T_time_stamp 0 year 0 3 000 1 month 1 12 January December 0 month not specified 2 day 1 31 0 day not specified 3 hour 0 23 4 minute 0 59 5 second 0 59 85 SNVT_zerospan 0 zero offset 163 84 163 835 1 s...

Страница 19: ...ondition 14 Fire Pre alarm condition 15 Fire Trouble fault condition 16 Fire Supervisory condition 17 Fire Alarm condition in Test Mode 18 Fire Pre Alarm condition in Test Mode 19 Fire Maximum environ...

Страница 20: ...normal 1 emergency pressurize 2 emergency depressurize 3 emergency purge 4 emergency shutdown 5 emergency fire 106 SNVT_temp_setpt 0 C occupied cool 273 17 327 66 1 C standby cool 273 17 327 66 2 C u...

Страница 21: ...6 Unused The next 16 override values apply to the first device or group 17 Override position percentage use percent field 18 Override flow in liters sec use flow field 19 Override flow percentage use...

Страница 22: ...ot conditioned fan turned on 10 Cooling with compressor not running 11 Ice making mode 12 Max Heat 13 Economy 14 Dehumid 15 Calibrate 16 Emergency Cool 17 Emergency Steam 18 Max Cool 19 HVC Load 20 No...

Страница 23: ...ble 2 chiller state 1 in alarm 3 1 run is enabled 4 1 local 5 1 limited 6 1 chilled water flow 7 1 conditioned water flow 128 SNVT_tod_event 0 current scheduled occupancy state 0 Area is occupied 1 Ar...

Страница 24: ...To obtain and install Echelon software 1 Go to www echelon com downloads 2 Log in or create a new login account 3 In Search for software in select Recommended Downloads click Find then download Open...

Страница 25: ...e the service pin on the LonWorks device you want to get information from The device number is displayed in the window CAUTION Holding the service pin for 3 seconds or longer can delete memory from so...

Страница 26: ...to install the software 6 Unzip the file that you downloaded for the LonWorks SLTA 10 Serial LonTalk R Adapter Software 7 Run slta10_Win exe to install the software Make note of the numeric base for...

Страница 27: ...tion from The device number is displayed in the window CAUTION Holding the service pin for 3 seconds or longer can delete memory from some third party devices TIP For some VAV devices the connected se...

Страница 28: ...able with a hub The iLon10 must also be connected to the LonWorks network segment 8 On the computer select Start Control Panel 9 Double click LonWorks Interfaces 10 Click Add 11 Type a name such as iL...

Страница 29: ...y also function as a service pin 22 Type G to go to the device menu 23 Type the device number then click Enter 24 Type D then press Enter for all domain tables 25 Type N then press Enter for all netwo...

Страница 30: ...All rights reserved 26 Important changes to this document are listed below Minor changes such as typographical or formatting errors are not listed Date Topic Change description Code 5 24 18 Overview A...

Страница 31: ......

Страница 32: ...CARRIER CORPORATION 2018 A member of the United Technologies Corporation family Stock symbol UTX Catalog No 11 808 430 01 5 24 2018...

Отзывы: