4
4. MODELS
HEAT PUMP
System
Model
Indoor Unit
Model
Outdoor Unit
Model
53QC36-708
42QC36-708
38QC36-708
53QC48-508
42QC48-708
38QC48-508
Notes:
53 = Split System
42 = Indoor Unit
38 = Outdoor Unit
Q = Heat Pump
C = Cassette
7 = Power supply 220-240/1/50
5 = Power supply 380-420/3/50
0 = Wireless remote control
8 = Miraco - Carrier
5. OPERATING LIMITS
COOLING
HEATING
Difference
Dry Bulb
Temp. C°
Wet Bulb
Temp. C°
Difference
Dry Bulb
Temp. C°
Wet Bulb
Temp. C°
Indoor temperature
Maximum
Minimum
32
21
23
15
Indoor temperature
Maximum
27
-
Outdoor temperature
Maximum
Minimum
46
20
-
-
Outdoor temperature
Maximum
Minimum
24
2
18
1
MAIN POWER SUPPLY
System
Model
Nominal
Power Supply
V/PH/HZ
Minimum
Voltage
Maximum
Voltage
53QC36-708
200-240/1/50
198
254
53QC48-508
380-420/3/50
342
462
NOTES:
* When the unit is operated above or below these limits for a long time, system diagnostics
may detect a malfunction and the unit will not operate properly.
** During heat pump operation, the system will undergo several defrost cycles to eliminate ice
that might possibly collect on the outdoor unit in very low ambient temperatures.
After completions of defrost cycle, the system will normally operate