T-372
4–60
7-1
High Pressure Switch Open
Pass / Fail / Skip Result, STS, DPT or CPT (if equipped)
Input values that component closes
8-0
Perishable Mode Heat Test
Pass / Fail / Skip Result, STS, time it takes to heat to 16°C (60°F)
8-1
Perishable Mode Pulldown Test Pass / Fail / Skip Result, STS, time it takes to pull down to 0°C (32°F)
8-2
Perishable Mode Maintain Test Pass / Fail / Skip Result, Averaged DataCORDER supply temperature
(SRS) over last recording interval.
9-0
Defrost Test
Pass / Fail / Skip Result, DTS reading at end of test, line voltage, line
frequency, time in defrost.
10-0 Frozen Mode Heat Test
Pass / Fail / Skip Result, STS, time unit is in heat.
10-1 Frozen Mode Pulldown Test
Pass / Fail / Skip Result, STS, time to pull down unit to -17.8°C (0°F).
10-2 Frozen Mode Maintain Test
Pass / Fail / Skip Result, Averaged DataCORDER return temperature
(RRS) over last recording interval.
Table 4–10 DataCORDER Pre-Trip Result Records (Continued)
Test Title
Data