3–5
T-372
3.1.6
Water-Cooled Condenser Section
The unit may contain a water-cooled condenser (WCC) installed as an option. When operating on the water-cooled
condenser, the condenser fan is deactivated by a water pressure switch or condenser fan switch.
Brazed Plate Water-Cooled Condenser
The brazed plate water-cooled condenser section (see
) consists of the brazed plate water-cooled
condenser, water couplings, a water pressure switch and a fusible plug. The receiver is retained in this
configuration and the brazed plate heat exchanger is placed between the air-cooled condenser and the receiver.
Figure 3.5 Brazed Plate Water-Cooled Condenser
1) Water-Cooled Condenser (WCC)
2) Coupling (Water In)
3) Self Draining Coupling (Water Out)
4) Water Pressure Switch (WP)
- - - - -
4
1
2
3